Download Print this page

JVC AV-20NX3 Service Manual page 33

Hide thumbs Also See for AV-20NX3:

Advertisement

[VIDEO - 2 SET : COMPONENT, fv: 50/60Hz mode]
Measuring
Item
instrument
Adjustment
Signal
of
generator
H. POSITION
Remote
control unit
C
VSM PRESET SETTING
Measuring
Item
instrument
Setting of
Remote
VSM
control unit
PRESET
SUB MENU 4. VSM PRESET
BRIGHT
TINT
COLOUR
BRIGHT
CONT
SHARP
MENU 89: SELECT
MENU - / + : OPERATE
Test point
Adjustment part
5. HOR. POSITION
D
Test point
Adjustment part
1. TINT
2. COLOUR
3. BRIGHT
4. CONT
5. SHARP
**
**
**
**
**
DISPLAY : EXIT
No. 52079
Description
1. Receive a PAL circle pattern signal to VIDEO-2 terminal.
2. Select VIDEO-2 SET from the MENU and set VIDEO-2 SET to
COMPONENT.
3. Select 3. DEF from the SERVICE MENU.
4. Select 5. HOR. POSITION with the MENU &/^ key.
5. Set the initial setting value of 5. HOR. POSITION with the MENU
*/Tkey.
6 Adjust 5. HOR POSITION to make "C=D" with the MENU */Tkey.
7. Press the DISPLAY key twice to return to the normal screen.
Description
1. Select 4. VSM PRESET from the SERVICE MENU.
2. Select BRIGHT with the PICTURE MODE key.
3. Adjust the MENU &/^ key and MENU */Tkey to reset the set
values of 1. TINT – 5. SHARP to the values shown in the table.
4. Respectively select the VSM PRESET mode for SOFT and STAND-
ARD, and make similar adjustment as in 3 above.
5. Press the DISPLAY key twice to return to the normal screen.
[Setting Values for SUB MENU 4. VSM PRESET]
VSM preset
VSM
mode
BRIGHT
Setting item
1. TINT
SETTING VALUE
2. COLOUR
SETTING VALUE
3. BRIGHT
SETTING VALUE
4. CONT
SETTING VALUE
5. SHARP
SETTING VALUE
AV-20NX3
STANDARD
SOFT
15
15
15
30
15
11
15
0
33

Advertisement