Download Print this page

JVC AV-20NX3 Service Manual page 31

Hide thumbs Also See for AV-20NX3:

Advertisement

Measuring
Item
instrument
Adjustment
Signal
of
generator
CORNER
Remote
control unit
Adjustment
Signal
of
generator
H. PARALLEL
Remote
control unit
Adjustment
Signal
of
generator
H. BOW
Remote
control unit
Test point
Adjustment part
9. UP CORNER
10. DW CORNER
11. HOR. PARALL
12. HOR. BOW
Straight
32. Select 9. UP CORNER with the MENU &/^ key.
33. Set the initial setting value of 9. UP CORNER with the MENU
*/Tkey.
34. Select 10. DW CORNER with the MENU &/^ key.
35. Set the initial setting value of 10. DW CORNER with the MENU
*/Tkey.
36. Adjust 9. UP CORNER and 10. DW CORNER so that the vertical
lines at the four corners on the screen are straight.
37. Select 11. HOR. PARALL with the MENU &/^ key.
38. Set the initial setting value of 11. HOR. PARALL with the MENU
*/Tkey.
39. Adjust 11. HOR. PARALL to optimize the parallelogram distortion.
40. Select 12. HOR. BOW with the MENU &/^ key.
41. Set the initial setting value of 12. HOR. BOW with the MENU */
Tkey.
42. Adjust 12. HOR. BOW to optimize the horizontal arc distortion.
43. Press the DISPLAY key twice to return to the normal screen.
No. 52079
AV-20NX3
Description
31

Advertisement

loading