Download Print this page

JVC AV-20NX3 Service Manual page 25

Hide thumbs Also See for AV-20NX3:

Advertisement

Measuring
Item
instrument
Adjustment
Signal
of
generator
SIDE PIN
Remote
control unit
Straight
Adjustment
Signal
of
generator
TRAPEZIUM
Remote
control unit
Parallel
Adjustment
Signal
of
generator
V.S-CURVE
Remote
control unit
Test point
Adjustment part
7. EW-PIN
8. EW-TRAPEZ
4. VER. SCURVE
TOP
CENTRE
BOTTOM
No. 52079
Description
23. Select 7. EW-PIN with the MENU &/^ key.
24. Set the initial setting value of 7. EW-PIN with the MENU */Tkey.
25. Adjust 7. EW-PIN so that the first vertical lines at the left and right
edges on the screen are straight.
26. Select 8. EW-TRAPEZ with the MENU &/^ key.
27. Set the initial setting value of 8. EW-TRAPEZ with the MENU
*/Tkey.
28. Adjust 8. EW-TRAPEZ so that the vertical lines at the left and right
edges on the screen are in parallel.
29. Select 4. VER. SCURVE with the MENU &/^ key.
30. Set the initial setting value of 4. VER. SCURVE with the MENU
*/Tkey.
31. Adjust 4. VER. SCURVE so that the spaces of each line on TOP,
CENTRE and BOTTOM become uniform.
(to be continued)
AV-20NX3
25

Advertisement