Nibe Contura Ci8 Manual
Hide thumbs Also See for Contura Ci8:

Advertisement

Quick Links

Ci8
Ci8 Left
Ci8 Right
Ci8G
Ci8G Left
Ci8G Right
contura.eu

Advertisement

loading
Need help?

Need help?

Do you have a question about the Contura Ci8 and is the answer not in the manual?

Questions and answers

Summary of Contents for Nibe Contura Ci8

  • Page 1 Ci8 Left Ci8 Right Ci8G Ci8G Left Ci8G Right contura.eu...
  • Page 2 Einzelheiten Fakta Fakta Inbyggnadsexempel Installationsbeispiele Innbyggingseksempel Måttskiss Maßskizze Målskisse Prestandadeklaration Leistungsdeklaration Ytelseserklæring Montering Montage Montering Données Techniques Facts Fakta Exemple d’encastrement Recess example Indbygningseksempel Schéma dimensionnel Dimensions diagram Målskitser Déclaration des performance Declaration of performance Præstationserklæring Montage Assembly Montering Tiedot Dati Tecnici Gegevens Asennusesimerkki...
  • Page 3 Données Techniques 5-9 kW 530 mm 735 mm 365 mm 100 kg Installation réalisée par un Structure portante Puissance nominale 7 kW Taux de rendement 77 % professionnel S’assurer que le solivage en bois du plancher Température des gaz de supporte la charge du poêle et de la cheminée.
  • Page 4 Encastrement de l’insert Étanchéité Pour l’encastrement de l’insert, les murs concomitants qui ne sont pas classés comme mur pare-feu ou estimés pour d’autres raisons comme L’encastrement ne doit pas atteindre le plafond ; un espace d’au moins 20 inaptes à une charge thermique, devront être protégés par un matériau de mm doit être prévu entre l’encastrement et le plafond.
  • Page 5 Exemple d’ e ncastrement Les dimensions indiquées sont Mur en matériau inflammable les valeurs minimales à ne pas dépasser, sauf indication contraire. Protection murale ventilée, constituée d’une plaque de silicate de calcium d’au moins 40 mm et d’une lame d’air. La plaque doit intégrer une lame d’air de 20 mm contre le mur combustible, la lame d’air doit avoir un débit d’air libre sur les bords inférieur et supérieur, voir le schéma de principe de droite.
  • Page 6 Exemple d’ e ncastrement Avtätning Étanchéité Area ut min. 200 cm Section sortie mini 200 cm Area ut min. 200 cm Section sortie mini 200 cm 20 mm Luftspalt Lame d’air 20 mm Lame d’air 20 mm 20 mm Luftspalt Section entrée mini 300 cm Section entrée mini 300 cm Area in min.
  • Page 7 Schéma dimensionnel La distance minimale devant la porte de l’insert à un élément de construction ou d’ameublement inflammable doit être de 1,4 mètre. Ø150 Ø150 Manchon d’arrivée Manchon d’arrivée d’air Ø65 d’air Ø65...
  • Page 8 Température des fumées dans le conduit de rac- 389 °C cordement en fonctionnement nominal Le soussigné est seul responsable de la fabrication et de la conformité des performances déclarées. Niklas Gunnarsson, Responsable de division NIBE STOVES Markaryd (suède), 1 août 2020...
  • Page 9 Montering Montage Før montering Om insatsen behöver läggas ned för att Wenn der Einsatz in liegender Position Hvis innsatsen må legges ned for å förflyttas bör lösa delar demonteras. versetzt werden muss, sind lose flyttes, bør løse deler demonteres. Demontering av eldstadsbeklädnad beskrivs i Komponenten zu demontieren.
  • Page 10 Ci8 Left / Right Handle with care!
  • Page 11 Handle with care!
  • Page 12 Handle with care!
  • Page 13 Handle with care!
  • Page 14 For installation in the UK and in smoke control areas Mandatory for smoke control areas Contura i8, 7 kW woodburning stoves has been recommended as The permanent stop must be installed if the appliance is to be suitable for use in smoke control areas. This when burning wood used in a smoke control area, this stop must not be removed in logs and operated in accordance with these instructions and when smoke control areas, otherwise an offence will be committed if...
  • Page 17 Installation i befi ntlig öppen eldstad Installation i eksisterende åbent ildsted Insatsen kan installeras som spiskassett i befintlig godkänd Indsatsen kan installeres som pejseindsats i et eksisterende öppen eldstad. Runt om insatsen skall det vara minst 10 mm godkendt åbent ildsted. Rundt om indsatsen skal der være luftspalt, detta pga.
  • Page 18 Anslutningsstos bakåt Anslutningsstos nedåt Används då utrymme finns bakåt. Används då utrymme inte finns bakåt. Anschlussstutzen nach hinten Anschlussstutzen nach unten Falls nach hinten ausreichend Platz vorhanden ist. Falls nach hinten nicht ausreichend Platz vorhanden ist. Tilkoblingsstuss bak Tilkoblingsstuss nedover Brukes når det ikke er plass bak.
  • Page 19 Anslutning till befi ntlig murad skorsten Tilslutning til eksisterende muret skorsten För enklast montage rekomenderas att använda flexibel slang Det anbefales at benytte en fleksibel slange for den letteste (säljs som tillbehör). Fäst stosen i slangen. Anslut och täta mellan montering (sælges som tilbehør).
  • Page 23 Ø 6 mm...
  • Page 25 3 m m Ci8 Left / Right...
  • Page 28 Ci8 Left / Right...
  • Page 29 Återmontera de invändiga delarna i Monter de indvendige dele igen i omvendt omvänd ordning. rækkefølge. Bauen Sie die restlichen Komponenten in Asenna sisäosat päinvastaisessa umgekehrter Reihenfolge wieder ein. järjestyksessä. Sett de innvendige delene tilbake på plass Rimontare i componenti interni i motsatt rekkefølge.
  • Page 32 811433 IAV SE-EX Ci8-1 NIBE AB · Box 134 · 285 23 Markaryd · Sweden 2020-08-31 contura.eu...

This manual is also suitable for:

Contura ci8 leftContura ci8 rightContura ci8gContura ci8g leftContura ci8g right