13. Error Code Listing ............................30 14. Curtain Movement Time (sec.) Vs. Distance (inches/cm.) ................31 15. Program Data Sheet ............................32 16. Warranty ....................... Error! Bookmark not defined. Part No. 4801-0150 Rev 1-20 Farm Hand Swine Finisher 5 Stage Table of Contents...
When this controller is used in a life support heating and ventilation system where failure could result in loss or injury, the user should provide adequate back-up, or accept the risk of such loss or injury! Part No. 4801-0150 Rev 1-20 Farm Hand Swine Finisher 5 Stage 3 of 33...
Stage Status Indicators The Farm Hand Swine Finisher 5 Stage Controller is designed to be one of the simplest controllers on the market to operate, but to also be one of the most powerful. The Swine Finisher has three main regions on the facepad that you need to be concerned with. First is the main display.
Look at the stage status indicators. If the light for stage 1 is lit, the parameter you are programming is for stage 1. To go to stage 2, continue to press the mode button until the stage 2 stage indicator light is lit. Part No. 4801-0150 Rev 1-20 Farm Hand Swine Finisher 5 Stage 5 of 33...
The average temperature of sensor 1 and sensor 2 is used. 5.1.2 Stage Mode (P2) The Farm Hand Swine Finisher is a very intelligent controller, therefore, it needs to not only know whether this is a heating or cooling stage but also what type of cooling stage. The Farm Hand Swine Finisher reacts not only to temperature but also curtain position.
This mode setting only works when the controller is in tunnel mode. 5.1.3 Stage Mode (P3) The Farm Hand Swine Finisher is equipped to satisfy any of your minimum ventilation needs for regular runtime timers and to cool timers. 00 = No Timer Select 0 for the timer setting if you do not want the stage to be on a timer.
Curve Conditions This curve is optimized for use with Cumberland’s line of Funnel Flow Fans that are 24” or less. Also, line voltage must be Single Phase. This curve lends itself better to operation of 36” fans. The power distributed at each percentage is somewhat greater than that of curve 0.
This sets the minimum Runtime percentage that a cool timer stage can operate. 5.4 PC Compatible Network Parameters This option requires Cumberland’s Farm Manager Software. The controller has 3 functions which are used to set it up on the Cumberland PC compatible inter-controller network (HHNet). These are: P40 - HHNet Address HHNet allows you to connect up to 32 controllers on a single communications port of your personal computer (PC).
If it is a power ventilated house the controller will leave the inlet curtain closed until tunnel mode is entered. This switch must be set to ON if you have a Power Ventilated house. Part No. 4801-0150 Rev 1-20 Farm Hand Swine Finisher 5 Stage 10 of 33...
Installation Kit Fuse Kit Sensors Manual 2. Hang Farm Hand Swine Finisher with four screws and the plastic mounting brackets included. 3. Make sure all power supplies are disconnected before breaking any wires, or reaching into the enclosure. 4. Open Swine Finisher and find all connections. Refer to wiring diagrams in back of this manual.
2 - Cool Timer 81 F Maximum On Point P4 - On Point 75 F Minimum On Point P5 - Off Point Minimum Percentage Minimum Runtime Percent Part No. 4801-0150 Rev 1-20 Farm Hand Swine Finisher 5 Stage 13 of 33...
5. Press the Mode button until P3 is displayed. This parameter allows you to put a stage on the system timer (5 or 10 minutes). 6. Press the + or - button until a 0 is displayed. Part No. 4801-0150 Rev 1-20 Farm Hand Swine Finisher 5 Stage 15 of 33...
3. Remove the screwdriver, and tug slightly on the wire to check that it is snug. Warning! Do not connect more than twelve (12) amps of load to any one stage. Part No. 4801-0150 Rev 1-20 Farm Hand Swine Finisher 5 Stage 16 of 33...
Inset A Common from Relay Panel Inset B To Relay Panel Stage 1 Stage 2 STAGES OUT Stage 3 Stage 4 Stage 5 Part No. 4801-0150 Rev 1-20 Farm Hand Swine Finisher 5 Stage 17 of 33...
Warning: Do not connect more than 12 amps of load to a single stage! Warning: Check that the stage jumpers are removed when connecting a load directly to the controller. Note: Cumberland recommends the use of an external contactor or relay panel to drive equipment. Part No. 4801-0150 Rev 1-20...
Note: If you are tunneling with this controller, the inlet machine must be connected to “Curtain 2”. Your main curtain should be connected to “Curtain 1” Part No. 4801-0150 Rev 1-20 Farm Hand Swine Finisher 5 Stage 19 of 33...
Curtain 1 Curtain 2 PRESSURE AC POWER HH NET STAGES OUT VAR FANS Signal Signal Swine Finisher Inset A VAR FANS Breaker H ot Panel N eutral Part No. 4801-0150 Rev 1-20 Farm Hand Swine Finisher 5 Stage 20 of 33...
Inset A SENSORS Curtain 1 Curtain 2 PRESSURE AC POWER HH NET STAGES OUT VAR FANS Signal Signal Swine Finisher White Shield Black SENSORS Inset A Part No. 4801-0150 Rev 1-20 Farm Hand Swine Finisher 5 Stage 21 of 33...
Note: If using 110 VAC, the neutral, or return, wire must be connected to terminal L2. This will ensure proper operation of the variable speed stages. Part No. 4801-0150 Rev 1-20 Farm Hand Swine Finisher 5 Stage 22 of 33...
Note: The internal wiring shows the condition of the alarm relay during normal conditions (no alarm present). During an alarm condition, the contact positions will be reversed. Part No. 4801-0150 Rev 1-20 Farm Hand Swine Finisher 5 Stage 24 of 33...
(Cycle time of 3 means that the curtain will move up or down (or remain stationary) depending upon temperature for its runtime once every 3 minutes.) Part No. 4801-0150 Rev 1-20 Farm Hand Swine Finisher 5 Stage 25 of 33...
Page 26
Press the + and/or - buttons until the correct reading is seen in the main display. (See Sensor Calibration) Part No. 4801-0150 Rev 1-20 Farm Hand Swine Finisher 5 Stage 26 of 33...
Page 27
‘B’ could be used to store separate summer/winter programs for instance. The ON position is for Program A, and the OFF position is for Program B. Part No. 4801-0150 Rev 1-20 Farm Hand Swine Finisher 5 Stage 27 of 33...
If the system is using 110 VAC, make sure that the neutral wire is connected to L1, and the Hot wire is Connected to L2 Make sure a proper earth ground is connected to the controller. Part No. 4801-0150 Rev 1-20 Farm Hand Swine Finisher 5 Stage 28 of 33...
0=Off Timer 02=Sensor 2 2=Cool Stir 1=On Normal Timer 12=Avg. Sen 1&2 3=Cool Neg 2=On Cool Timer 4=Cool Neg Tunnel 5=Cool Tunnel (Version 15 or above) Part No. 4801-0150 Rev 1-20 Farm Hand Swine Finisher 5 Stage 32 of 33...