Henny Penny SmartCombi ESC 615 Troubleshooting Manual page 23

Error messages & troubleshooting electric and gas combi
Hide thumbs Also See for SmartCombi ESC 615:
Table of Contents

Advertisement

SmartCombi™ Service
Does the error message seem only
sometimes ?
Yes
Is the fresh air area free of dirt (left
hand side at the bottom of the
oven )?
Yes
A device which produces high
temperatures is next to the left side.
Change structural situation.
Explanation:
K2 energizes D0
K3 energizes D1
K5 energizes D2
Fast speed mode:
x.1 approx. 1450 rpm
x.2 approx. 1600 rpm
Medium speed mode:
x.1 approx. 750 rpm
x.2 approx. 1000 rpm
Slow speed mode:
x.1 approx. 450 rpm
x.2 approx. 600 rpm
Check cooling fan at the tube carrier box and at the frequency
Kühllüfter am Schlauchaufrollkasten und Frequenzumrichter
controller. Replace fan.
prüfen. Ggf. defekten Lüfter tauschen.
No
Clean fresh air area.
No
Fan mode
Right slow
Right medium
Right fast
Left slow
Left medium
Left fast
1 = 230V measured against N
0 = no voltage
Input
D2 D1
D0
1
1
1
1
1
0
0
1
0
1
0
0
1
0
1
0
0
1
23