RANS S-21 OUTBOUND
14.
For safety reasons the Battery to Solenoid Cable should only be attached to the
positive (+) battery terminal just prior to engine start or other electrical testing.
TITAN X-340 - FUEL SYSTEM - FIREWALL FORWARD
Refer to the parts pages and select the required components for assembly.
FUEL LINE INSTALLATION
1.
Connect Fuel Line Assembly from OUTLET side of Gascolator to INLET side of
Engine Fuel Pump as shown on Parts Page. Tighten all connections.
2.
Connect Fuel Line supplied with engine from Engine Fuel Pump to Fuel Injection
Servo with indicted fitting.
3.
If installing a Fuel Flow Transducer (i.e. Electronics International FT60), re-route
the fuel lines as shown in the parts manual using the Optional – Fuel Line
Assembly – Transducer to Fuel Servo. This Optional Fuel Line Assembly is
available from RANS Aircraft Parts.
FUEL PUMP DRAIN INSTALLATION
1.
Install 90-degree Elbow into Mechanical Fuel Pump.
2.
Cut Drain Line from provided Aluminum Tube. Be sure to place a 45° bevel at the
lower end of tube. Orientate bevel to the aft when installing.
3.
Locate Angle Bracket on lower flange of firewall. Drill #11 and rivet in place. Be
sure to place far enough forward to allow drain tube to clear firewall when
clamped in place. Also, locate away from exhaust, near center of firewall.
4.
Bolt Plain Clamp with drain tube to Angle Bracket. Beveled end of drain tube
should extend 1" or more below firewall. Route Black Fuel Line to drain tube. Cut
to length, as needed, and attach to hose fitting and drain tube. Tighten or secure
all connections.
TEXT MANUAL
09/11/2018
11-7
Need help?
Do you have a question about the S-21 OUTBOUND and is the answer not in the manual?