SW 6 Component Operation, cont'd
instructions that appear on the screen. The program
occupies approximately 1 MB (megabyte) of hard drive
space.
By default, the Windows installation creates a C:\UNIVSW
directory, and it places two icons (Universal Switcher
Control Pgm and Universal Switcher Help) into a group or
folder named "Extron Electronics".

Using the software

To run the software, do the following:
1. Double-click on the Universal Switcher Control Pgm
2. Click on the comm port that is connected to the
switcher's RS-232 port.
The Universal SW Control Program window appears
(figure 32). It displays the current mode and input
selection.
Figure 32 — Universal SW Control Program
3. Using normal Windows controls, you can perform the
same adjustments as from the front panel.
4-10
SW AR MX, SW AR MX HV, SW 6 Component • Operation
icon in the Extron Electronics group or
folder.
The Comm menu appears on the
screen.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
For information about program features, you can access the
Help program in any of the following ways:
• From the Extron Electronics program folder or group,
double-click on the Universal Switcher
Help icon.
• From within the Universal SW Control Program, click on
the Help menu on the main screen.
• From within the Universal SW Control Program, press the
F1 key.

Power Supply

The SW AR MX, SW AR MX HV, and SW 6 Component
switchers are equipped with an internal power supply that
operates from any AC line voltage in the 100—240VAC,
50/60Hz range. No configuration is required.

Replacing the fuse

The power supply is protected by a 400 mA, 250V, slow
blow fuse. The fuse is in a holder located below the AC
connector on the rear panel.
To change the fuse, do the following:
1. If the power cord is attached, disconnect it from the
switcher.
2. Insert a small screwdriver blade into the slot provided
at the top of the fuse holder, and pry the holder
open (figure 33).
1
3
5
6
4
2
INPUTS
INPUTS
Figure 33 — Opening the fuse holder
3. Pull the fuse holder out.
4. Place a new fuse in the fuse holder. Each switcher ships
with a spare fuse mounted inside the fuse holder.
SW AR MX, SW AR MX HV, SW 6 Component • Operation
Fuse Holder
90-240 VAC, 50/60 Hz
FUSE: 250V, 400mA SLO-BLO
4-11