4.2 AC CURRENT
Range
Resolution
====================================================
20A
0.01A
200A
0.1A
1000A
1A
Frequency Range: 50Hz to 60Hz
Response: Average, Calibrated in rms of sine wave
Overload protection: 1200A within 60 seconds. Jaw Opening: 50mm
4.3 INSULATION TEST
(With option 500V insulation tester unit)
Range
Resolution
±2.0%of rdg±2 digits
20M
10k
±4.0%of rdg±2 digits
2000M
1M
±5.0%of rdg±2 digits
4.4 AC VOLTAGE
Range
Resolution
200V
0.1V
750V
1V
Input Impedance: ≥9M on all ranges
Overload protection: 1000V DC or 750V AC on all ranges
Frequency Range:(50Hz to 400Hz) /≤ 600V; (50Hz to 200Hz) / 750V.
Response: Average, calibrated in rms of sine wave
4.5 DC VOLTAGE
Range
Resolution
200mV
0.1mV
2V
1mV
20V
10mV
200V
0.1V
1000V
1V
Input Impedance: ≥9M
Overload protection: 250Vrms AC for 200mV range, 1000V DC or 750V
AC for other range.
Accuracy
±4.0%of rdg±5 digits
±2.5%of rdg±5 digits
±3.0%of rdg±10 digits
M266Fには20Aレンジはありません。
Accuracy
Note
≤ 500M
> 500M
Accuracy
±1.0%of rdg±5 digits
±1.2%of rdg±5 digits
Accuracy
±0.5%of rdg±1 digit
±0.5%of rdg±3 digits
±0.8%of rdg±3 digits
- 7 -
4.6 RESISTANCE
Range
Resolution
200
0.1
2k
1
20k
10
200k
100
2M
1k
Overload protection: 250V DC or 250Vrms AC on all ranges.
Open circuit voltage: 700mV
4.7 TEMPERATURE (FOR M266C ONLY)
RANGE
RESOLUTION
0℃ to 400℃
( 32℉ to 752℉)
0℃ to
1℃
750℃
1.0% of rdg  3 digits 2.0% of rdg 3 digits
32℉ to
1℉
1382℉
4.8 FREQUENCY (FOR M266F ONLY)
Range
Resolution
2kHz
1Hz
5. ACCESSORIES
COME WITH THE CLAMP METER
Test Leads
Model: T3000
Battery
9V 6F22 or equivalent
Operation Manual
Temperature probe(for M266C only)
Accuracy
±1.0%of rdg±5 digits
±1.0%of rdg±8 digits
Accuracy
401℃ to 750℃
( 754℉ to 1382℉)
Accuracy
±2.0%of rdg±5 digits