DANGER!
• Do not attempt to adjust your Elite arm until everything you intend
to mount to the arm is mounted.
• Arm must be completely horizontal (extended) before adjusting the
arm's tension. Failure to do so will damage the arm and void the
warranty.
• Never loosen or remove any of the shoulder bolts.
Doing so will cause the arm to immediately come
IMPORTANT
If Mounting To Wall
ATTACH WALL
PLATE TO WALL
Locate stud and mark top
hole, drill 11/64 pilot hole
and insert #14 screw and
tighten slightly. Using a
level, mark lower hole
and drill pilot hole, insert
#14 screw and, with
unit level, tighten both
screws. ICW supplies
#14 wood screws. If
installing
onto
metal
studs, you will need
to replace with proper
metal stud fasteners.
If Mounting To A Desk
ATTACH TO DESK
Drill a 3/8 hole through the horizontal
surface you intend to mount to. Screw
the 3/8 stud into your desk mount
as shown, the stud is found in your
hardware bag.
Push the 3/8 stud on desk mount
through the hole in the desk and slip
the large mounting washer over the
stud from underneath and secure in
place with the 3/8 nylock nut.
Page 1 of 3
ELITE DOUBLE ARM INSTALLATION
The elite arm contains high pressure gas springs.
The following cautions MusT be observed to avoid serious injury.
DO NOT use power tools to assemble or adjust the arm.
Use hand tools ONLY.
ICW recommends wood or metal stud mounting only.
ATTACH ELITE ARM TO WALL MOUNT
assembly
If you have any questions, please call 1-800-558-4435
apart with tremendous force, and could cause
serious injury.
• If equipment requiring AC power is mounted to this unit, have a
certified electrician inspect the installation.
• Failure to install this unit according to these instructions will void
all ICW warranties. If installed incorrectly, ICW is not liable for any
damage or injury caused by the unit.
Pass 3/8 bolt with bearing
assembly through wall mount
ear and into end of Elite
Arm. Secure Elite Arm over
wall mount using split lock
washer and nylock nut with
9/16 wrench provided and
5mm hex key.
Bearing
Torque bolt down to 204 in/
lbs (17 ft/lbs)
5mm
Black plastic beauty cap
If Mounting To A Pole
ATTACH TO POLE
Detach the pole mount from arm using the provided
5mm hex key. Separate the two sections of the
pole mount using the provided 5/32 hex key. Place
around the pole you are mounting to and fi rmly
reassemble the pole mount.
 MAXUMUM LOAD CAPACITY: 28 Lbs (12.7 kg)
ELITE DOUBLE ARM INSTRUCTIONS - rev 03/31/2015 pjm
9/16 wrench
(provided)

Advertisement

loading

Summary of Contents for ICW Elite ELP5220

  • Page 1 • Failure to install this unit according to these instructions will void • Never loosen or remove any of the shoulder bolts. all ICW warranties. If installed incorrectly, ICW is not liable for any Doing so will cause the arm to immediately come damage or injury caused by the unit. DO NOT use power tools to assemble or adjust the arm.
  • Page 2 ELITE DOUBLE ARM INSTRUCTIONS If you have any questions, please call 1-800-558-4435 iCWusA.com, inc. ATTACH PARALINK KEYBOARD TO MONITOR ATTACH PARALINK KEYBOARD TRAY • Remove beauty cap on Attach the Paralink Paralink. Beauty cap keyboard mount to the • Remove screw using monitor mount by using Screw 3/16”...
  • Page 3 ELITE DOUBLE ARM INSTRUCTIONS If you have any questions, please call 1-800-558-4435 ICWUSA.com, Inc. ADJUST BALL VESA ADJUST PARALINK & MONITOR TILT, ROTATION Slider Knob TENSION & HEIGHT • Gently hold sides of monitor. Tilt and Use the slider knob rotate to desired to loosen the slider to position with...

This manual is also suitable for: