Ubiquiti UVC­-G3-­DOME Quick Start Manual

Ubiquiti UVC­-G3-­DOME Quick Start Manual

Hide thumbs Also See for UVC­-G3-­DOME:

Advertisement

Quick Links

Package Contents
Camera
Flat Head Screws (Qty. 4)
Screw Anchors (Qty. 4)
Installation Requirements
Phillips screwdriver
Drill and drill bit (6 mm for wall­mounting or 3 mm for ceiling­mounting)
Cat5/6 cable for indoor installations
Outdoor Installation Requirements
Important: The UVC G3 Dome may be installed outdoors under an eave or
UVC­G3­DOME Quick Start Guide
Mounting Bracket
Keps Nuts (Qty. 4)
Ceiling Backing Plate
Screws (Qty. 4)

Advertisement

Table of Contents
loading

Summary of Contents for Ubiquiti UVC­-G3-­DOME

  • Page 1 UVC­G3­DOME Quick Start Guide Package Contents Camera Mounting Bracket Ceiling Backing Plate Flat Head Screws (Qty. 4) Keps Nuts (Qty. 4) Screws (Qty. 4) Screw Anchors (Qty. 4) Installation Requirements Phillips screwdriver Drill and drill bit (6 mm for wall­mounting or 3 mm for ceiling­mounting) Cat5/6 cable for indoor installations Outdoor Installation Requirements Important: The UVC G3 Dome may be installed outdoors under an eave or...
  • Page 2: Hardware Overview

    Mounting location should be at least 60 cm (2 ft) from the edge of the eave or ceiling. Cable feed must be pointed downwards when wall­mounted. Shielded Category 5 (or above) cabling with drain wire should be used for all outdoor wired Ethernet connections and should be grounded through the AC ground of the PoE. We recommend that you protect your networks from harmful outdoor environments and destructive ESD events with industrial­grade, shielded Ethernet cable from Ubiquiti. For more details, visit ui.com/toughcable Surge protection should be used for all outdoor installations. We recommend that you use two Ethernet Surge Protectors, model ETH­SP­G2, one near the UVC G3 Dome and the other at the entry point to the building. The ETH­SP­G2 will absorb power surges and safely discharge them into the ground. Hardware Overview...
  • Page 3 Cable Gland For outdoor installations, ensure the rubber Cable Gland is installed for added protection. Security Slot When removing the G3 Dome Camera from the Mounting Bracket, insert a paper clip in the Security Slot to release the Lock Tab and turn the G3 Camera counterclockwise. The LED will light steady blue during bootup. After bootup, the LED will flash until the camera is adopted by the NVR. Upon adoption the LED will light steady blue for 10 minutes and then turn off. Ethernet Port The Ethernet port is a 10/100 Ethernet port used to connect the power and should be connected to the LAN and DHCP server. Reset Button To reset the camera to factory defaults, press and hold the Reset button for more than 10 seconds while the camera is powered on. microSD Slot...
  • Page 4: Hardware Installation

    Reserved for future use. Hardware Installation Wall Mount 1.  2. ...
  • Page 5 Optional...
  • Page 6 3.  4. ...
  • Page 7 5.  6.  7. ...
  • Page 8 8.  Optional 9. ...
  • Page 9 10.  Ceiling Mount 1. ...
  • Page 10 2.  3. ...
  • Page 11 4. ...
  • Page 12 5.  6.  7. ...
  • Page 13 8.  9.  10. ...
  • Page 14: Adjusting The Camera Angle

    Adjusting the Camera Angle 1.  2.  3. ...
  • Page 15 4.  5. ...
  • Page 16: Connecting Power

    6.  Connecting Power The G3 DOME features auto­sensing 802.3af PoE and can be powered by any of the following: Ubiquiti UniFi Switch 802.3af PoE compliant switch Ubiquiti PoE Adapter (24V, 0.5A, not included) Connecting to a PoE Switch Connect the Ethernet cable from the G3 Dome Camera directly to a PoE port on the switch.
  • Page 17: Specifications

    Setting Up UniFi Protect via App Launch the UniFi Protect app and follow the on­screen instructions to complete setup. Specifications UVC­G3­DOME Dimensions Ø 132 x 60 mm (Ø 5.20 x 2.36") Weight 260 g (9.17 oz) Sensor 1/3" 4­Megapixel HDR Sensor Lens EFL 2.8 mm / F2.0 Viewing Angle Before Lens Correction 100.4° (H), 59.1° (V), 117.3° (D) After Lens Correction 87.8° (H), 55.4° (V), 96.4° (D) Night Mode IR LEDs with Mechanical ICR Filter Video Compression H.264 Resolution 1080p FHD (1920 x 1080) Maximum Frame Rate 30 FPS Image Settings Brightness, Contrast, Sharpness, Saturation, Noise Reduction, 50/60 Hz Microphone...
  • Page 18: Safety Notices

    UVC­G3­DOME Microphone Management Interface UniFi Protect Networking Interface (1) 10/100 Ethernet Port Max. Power Consumption Power Method 802.3af PoE / 24V Passive PoE Power Supply 802.3af PoE Switch Supported Voltage 24V to 48V Mounting Wall/Ceiling Mount Operating Temperature ­30 to 50° C (­22 to 122° F) Operating Humidity 20 to 90% Noncondensing Safety Notices 1. Read, follow, and keep these instructions. 2. Heed all warnings. 3. Only use attachments/accessories specified by the manufacturer. WARNING: Hot surface. Do not touch. WARNING: Do not use this product in location that can be submerged by water. WARNING: Avoid using this product during an electrical storm. There may be a remote risk of electric shock from lightning. Electrical Safety Information 1. Compliance is required with respect to voltage, frequency, and current requirements indicated on the manufacturer’s label. Connection to a different power source than those specified may result in improper operation, damage to the equipment or pose a fire hazard if the limitations are not followed. 2. There are no operator serviceable parts inside this equipment. Service should be provided only by a qualified service technician. Limited Warranty ui.com/support/warranty The limited warranty requires the use of arbitration to resolve disputes on an individual basis, and, where applicable, specify arbitration instead of jury trials or class actions. Compliance...
  • Page 19: Declaration Of Conformity

    Compliance Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions. 1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operations of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. ISED Canada CAN ICES­3(A)/NMB­3(A) Australia and New Zealand Warning: This equipment is compliant with Class A of CISPR 32. In a residential environment this equipment may cause radio interference. CE Marking CE marking on this product represents the product is in compliance with all directives that are applicable to it. WEEE Compliance Statement Declaration of Conformity Online Resources...
  • Page 20 © 2021 Ubiquiti Inc. All rights reserved.

Table of Contents