Ubiquiti UVC­-G3­-PRO Quick Start Manual

Ubiquiti UVC­-G3­-PRO Quick Start Manual

Hide thumbs Also See for UVC­-G3­-PRO:

Advertisement

Quick Links

Package Contents
Camera
Self­Tapping Screws (Qty. 2)
Installation Requirements
Pole­mounting: Two metal straps / hose clamps (not included)
Shielded Category 5 (or above) cabling with drain wire should be used for all
outdoor wired Ethernet connections and should be grounded through the AC
ground of the PoE.
We recommend that you protect your networks from harmful outdoor
environments and destructive ESD events with industrial­grade, shielded
Ethernet cable from Ubiquiti. For more details, visit ui.com/toughcable
Surge protection should be used for all outdoor installations. We recommend
that you use two Ethernet Surge Protectors, model ETH­SP, one near the
camera and the other at the entry point to the building. The ETH­SP will absorb
power surges and safely discharge them into the ground.
Hardware Overview
UVC­G3­PRO Quick Start Guide
Tightening Tool
Pole Mount Bracket
Screw Anchors (Qty. 2)
Machine Screws (Qty. 2)

Advertisement

Table of Contents
loading

Summary of Contents for Ubiquiti UVC­-G3­-PRO

  • Page 1 UVC­G3­PRO Quick Start Guide Package Contents Camera Tightening Tool Screw Anchors (Qty. 2) Self­Tapping Screws (Qty. 2) Pole Mount Bracket Machine Screws (Qty. 2) Installation Requirements Pole­mounting: Two metal straps / hose clamps (not included) Shielded Category 5 (or above) cabling with drain wire should be used for all outdoor wired Ethernet connections and should be grounded through the AC ground of the PoE. We recommend that you protect your networks from harmful outdoor environments and destructive ESD events with industrial­grade, shielded Ethernet cable from Ubiquiti. For more details, visit ui.com/toughcable Surge protection should be used for all outdoor installations. We recommend that you use two Ethernet Surge Protectors, model ETH­SP, one near the camera and the other at the entry point to the building. The ETH­SP will absorb power surges and safely discharge them into the ground. Hardware Overview...
  • Page 2: Hardware Installation

    Ethernet Port 10/100 RJ45 port connects to an 802.3af/802.3at or 24V Passive PoE switch for PoE power and data. Reset Button To reset to factory defaults, press and hold the Reset button for more than 10 seconds while the camera is powered on. Hardware Installation Wall/Ceiling Mount 1. ...
  • Page 3 2.  3. ...
  • Page 4 4.  5.  ...
  • Page 5 6. ...
  • Page 6 7.  8. ...
  • Page 7: Pole Mount

    9.  10. Proceed to the Connecting Power section. Pole Mount 1.  2. ...
  • Page 8 3.  4. ...
  • Page 9: Connecting Power

    5.  Connecting Power The UVC G3 Pro supports 802.3af, 802.3at, and 24V Passive PoE and can be powered by any 802.3af/802.3at or 24V Passive PoE compliant switch, such as a UniFi PoE Switch. Connect the Ethernet cable from the camera directly to a PoE port on the switch.
  • Page 10 Setting Up UniFi Protect via App Download and install the UniFi Protect app to configure the UVC­G3­PRO. Launch the UniFi Protect app and follow the on­screen instructions to complete setup. Adjusting the Camera View 1. ...
  • Page 11 2.  3.  4. ...
  • Page 12: Specifications

    5.  Specifications UVC­G3­PRO Dimensions Ø 86 x 153 mm (Ø 3.39 x 6.02") (Without Mounting Plate) Weight  700 g (1.54 lb) (Without Mounting Plate) Enclosure UV Stabilized Polycarbonate and Die­Cast Aluminum Networking Interface (1) 10/100 Ethernet Port Sensor Sony IMX290, 1/2.8" Lens 3­9 mm, f/1.2­f/2.1 Powered Zoom Lens Field of View   Wide 108° (H), 58° (V), 125° (D) Tele 37° (H), 20° (V), 43° (D) Night Mode IR LEDs with Mechanical IR Cut Filter Video Compression H.264 Resolution 1080p Full HD (1920 x 1080) Maximum Frame Rate 30 FPS Image Settings Flip, Brightness, Contrast, WDR, Hue, Infrared, Sharpness, Saturation, Denoise, 50/60 Hz Flicker...
  • Page 13: Safety Notices

    UVC­G3­PRO Sharpness, Saturation, Denoise, 50/60 Hz Flicker Reduction Management Interface   Managed Mode UniFi Protect Standalone Mode Camera Integrated Web UI Microphone Max. Power Consumption 12.5W Power Method IEEE 802.3af/at Type 2 PoE or 24V Passive PoE Power Supply 802.3af/802.3at or 24V Passive  PoE Switch Buttons Factory Reset Button Mounting Wall/Ceiling (Kits Included) Pole (Bracket Included) Operating Temperature ­20 to 50° C ­4 to 122° F Operating Humidity 0 to 90% Noncondensing Weatherproofing IP67 Safety Notices 1. Read, follow, and keep these instructions. 2. Heed all warnings. 3. Only use attachments/accessories specified by the manufacturer. WARNING: Hot surface. Do not touch. WARNING: Do not use this product in location that can be submerged by water. WARNING: Avoid using this product during an electrical storm. There may be a remote risk of electric shock from lightning. Electrical Safety Information 1. Compliance is required with respect to voltage, frequency, and current requirements indicated on the manufacturer’s label. Connection to a different power source than those specified may result in improper operation, damage to the equipment or pose a fire hazard if the limitations are not followed.
  • Page 14: Declaration Of Conformity

    Limited Warranty ui.com/support/warranty The limited warranty requires the use of arbitration to resolve disputes on an individual basis, and, where applicable, specify arbitration instead of jury trials or class actions. Compliance Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions. 1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operations of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. ISED Canada CAN ICES­3(A)/NMB­3(A) Australia and New Zealand Warning: This equipment is compliant with Class A of CISPR 32. In a residential environment this equipment may cause radio interference. CE Marking CE marking on this product represents the product is in compliance with all directives that are applicable to it. WEEE Compliance Statement Declaration of Conformity...
  • Page 15: Online Resources

    Online Resources © 2021 Ubiquiti Inc. All rights reserved.

Table of Contents