5. TROUBLESHOOTING [SHUTDOWN/ALARM Indications on the Instrument Panel]
A/S
Light:
Category of
Code
Action
Problem
Failed or discon-
E-31
SHUTDOWN:
On (flashing)
nected temperature
sensor 1
E-32
SHUTDOWN:
Failed or discon-
On (flashing)
nected temperature
sensor 2
Failed or
E-33
SHUTDOWN:
On (flashing)
disconnected
pressure sensor
E-41
SHUTDOWN:
Failed control
On (flashing)
device
E-42
SHUTDOWN:
Failed control
On (flashing)
device
E-43
SHUTDOWN:
Failed control
On (flashing)
device
E-21
ALARM:
Clogged air
On (flashing)
intake filter
E-59
ALARM:
Excessive load/
On (flashing)
unload
E-22
ALARM:
Low oil level
On (flashing)
(option)
E-15
SHUTDOWN:
Option
On (flashing)
E-54
ALARM:
Option
On (flashing)
AUTO START:
Instantaneous
On (flashing)
power
interruption
(IPS)
* Discharge temperature 1: Temperature at the outlet of the air end
Discharge temperature 2: Temperature at the outlet of the oil separator element
24
A
Causes
Shutdown
Yes
Failure or
Disconnect the power and check the TH1.
disconnection of
Replace it if necessary. Tightly reconnect
thermistor TH1
the TH1 wires.
Yes
Failure or
Disconnect the power and check the TH2.
disconnection of
Replace it if necessary. Tightly reconnect
thermistor TH2
the TH2 wires.
Yes
Failure or discon-
Disconnect the power and check the PS.
nection of pressure
Replace it if necessary. Tightly reconnect
sensor PS
the PS wires.
Yes
Failure of ROM
Disconnect and reconnect the power. If a
(or printed
problem still occurs, replace the printed
circuit board)
circuit board.
Yes
Failure of RAM
Disconnect and reconnect the power. If a
(or printed
problem still occurs, replace the printed
circuit board)
circuit board.
Yes
Failure of E
2
ROM
Disconnect and reconnect the power. If a
(or printed circuit
problem still occurs, replace the printed
board)
circuit board.
No
Clogging of air
Clean the air intake filter element.
intake filter
No
Total 1,000,000
Replace the consumable parts of suction
times loaded/
throttle valve.
unloaded
No
Low oil level
Yes
No
No
IPS of below 5
Check the power supply.
seconds
IPS of below 5
Check the power supply.
seconds
What Actions to Take
Mark
What and How
How to
to Detect
Reset
Operating
Automatically
temperature
reset.
below –30°C
Operating
Automatically
temperature
reset.
below –30°C
0 (zero) MPa
Automatically
during
reset.
operation.
Retrying action
Disconnect and
reconnect the
power.
Retrying action
Disconnect and
reconnect the
power.
Retrying action
Disconnect and
reconnect the
power.
Pressure
Press the
differential of
RESET button.
7.4 kPa
1,000,000 times
Hold down
SELECT and
press RESET.
IPS of 20 ms to
5 seconds
IPS of below 20
ms
A/S
History
31
32
33
41
42
43
21
59
22
15
54
03
04