Standard Specification - Hitachi HISCREW 2000 Series Instruction Manual

Rotary screw compressor
Table of Contents

Advertisement

12. STANDARD SPECIFICATION

Compressor Specification
Item
Operating gas
Suction pressure
Suction temperature
Discharge pressure
Discharge air capacity
Discharge temperature
Main motor output
Main motor type
Fan motor output
Fan motor type
Starter type
Lubricating oil
Lubricating oil filling amount
Capacity control type
Dryer outlet dew point (under pressure)
Dryer refrigerator nominal output
Condenser fan motor output
Coolant used
Total weight
Size (Width×Depth× Height)
NOTE (1)
means standard specifications.
(2) Discharge air capacity is a converted value according to the suction condition of the compressor.
(3) Dew point shown is the value measured in an environment with ambient temperature 30°C., discharge pressure 0.69 MPa.
(4) Do not select U-type control for 0.92MPa discharge pressure model.
(5) The values in the brackets are for the models with a built-in air dryer.
OSP-22S5A ( R ) I / S6A ( R ) I
Unit
OSP-22M5A ( R ) I / M6A ( R ) I
MPa
0.69
m
3
/min
3.8
kW
kW
NEW A OIL 2000 (genuine synthetic oil)
liter
S-type
U-type (suction throttle type) + I-type (vacuum type)
M-type
U-type (suction throttle type) + I-type (vacuum type) + P-type (auto start/stop)
kW
W
R407C (360 g)
kg
540 [590]
1,200
mm
Air
Ambient pressure
0 to 40 [5 to 40]
0.83
0.92
3.1
2.9
Atomospheric temperature + 15
22
Totally enclosed, external-fan cooled
0.75
Totally enclosed
Star-Delta Starting
8
10
1.1
×
25
1
×
×
890
1,260
OSP-37S5A ( R ) I / S6A ( R ) I
OSP-37M5A ( R ) I / M6A ( R ) I
0.69
0.83
6.3
5.3
37
1.5
13
×
25
2
R407C (600 g)
760 [830]
×
×
970
1,400
1,400
0.92
5.0
69

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents