5. TROUBLESHOOTING [SHUTDOWN/ALARM Indications on the Instrument Panel]
5.3 SHUTDOWN/ALARM Indications on the Instrument Panel
When a problem occurs, the SHUTDOWN, ALARM or AUTO START light flashes and the digital monitor displays
a corresponding ALARM or SHUTDOWN (as 'A/S' below) code. If this is the case, refer to the following table to
identify the cause. If you cannot identify the cause, or for the problem with a   mark in the table, contact a
Hitachi distributor.
A/S
Light:
Category of
Code
Action
Problem
E-17
SHUTDOWN:
Overloading
On (flashing)
E-18
SHUTDOWN:
High discharge
On (flashing)
temperature 1 (*)
E-23
ALARM:
High discharge
On (flashing)
temperature 1 (*)
E-19
SHUTDOWN:
Failed air dryer
On (flashing)
ALARM:
On (flashing)
E-01
SHUTDOWN:
Reversal phase
On (flashing)
connection
E-02
SHUTDOWN:
Phase-lacking
On (flashing)
connection
E-11
SHUTDOWN:
High discharge
On (flashing)
temperature 2 (*)
E-12
SHUTDOWN:
Abnormally
On (flashing)
high discharge
pressure
E-14
SHUTDOWN:
Option
On (flashing)
E-16
SHUTDOWN:
Answer error of
On (flashing)
contactor 42
E-51
SHUTDOWN:
Answer error of
On (flashing)
contactor 52
A
Causes
Shutdown
Yes
Failure of power
Check the power supply for a voltage drop
supply
and imbalance. Correct it if required.
High discharge
Check and correct the capacity control settings and/
pressure
or readjust the modulator valve, if the discharge pres-
sure is higher than the specification pressure.
High discharge
Check the oil separator element. Replace
pressure
it if it is clogged.
Failure of main motor
Check the motor for insulation resistance
etc.
and/or cooling fan motor
Failure of air end
Check the air end.
Yes
High ambient
Ventilate the room to reduce the ambient
temperature
temperature to 40°C.
Low oil level
Add oil. (Disconnect the power and make sure that the
discharge pressure gauge reads 0 MPa in advance.)
Dirty or clogged
Clean the cooling fins. See page 51.
oil cooler
Dirty or clogged
Replace the oil filter. See page 49.
oil filter
No
Same as
Same as the E-18 above
the E-18 above
Yes
Tripping of an air
See page 25.
dryer's protective
device during
No
operation
Yes
Power connected
Disconnect the power and change 2 of
in a reversal phase
the 3 power cord wires.
Yes
Power connected
Check the power supply. Tightly reconnect
with a lack of
the power cord wires.
phase
Yes
Failure of oil
Replace the oil separator element and the
separator
oil.
element
Yes
Failure of oil
Check the oil separator element. Replace
separator
if required.
element
Failure of
Disconnect the power and tightly reconnect
contactor 52
the 52 wires.
Yes
Yes
Failure of
Disconnect the power and check the 42.
contactor 42
Tightly reconnect the 42 wires. Replace the
(42 answer error)
42 if necessary.
Yes
Failure of
Disconnect the power and check the 52.
contactor 52
Tightly reconnect the 52 wires. Replace the
(52 answer error)
52 if necessary.
What Actions to Take
Mark
What and How
How to
to Detect
Reset
Tripping of
Press the reset
thermal
button of the
overload relay
thermal
overload relay.
Discharge
Press the
temperature 1
RESET button.
over 110°C
Discharge
Automatically
temperature 1
reset.
over 105°C
DIP switch SW1
Press the
No.2 set to OFF
RESET button.
DIP switch SW1
Press the
No.2 set to ON
RESET button.
Detected for 3
Disconnect and
seconds after
reconnect the
connecting the
power.
power
Detected for 3
Disconnect and
seconds after
reconnect the
connecting the
power.
power
Discharge
Press the
temperature 2
RESET button.
over 110°C
Detected during
Press the
delta operation
RESET button.
Detected during
Press the
delta operation
RESET button.
Detected during
Press the
star operation
RESET button.
A/S
History
17
18
23
19
19
01
02
11
12
12
14
16
51
23