Amana AVZC18 Installation & Service Reference page 7

Heat pump unit
Hide thumbs Also See for AVZC18:
Table of Contents

Advertisement

H
V
C
IGH
OLTAGE
ONNECTIONS
Route power supply and ground wires through the high voltage
port and terminate in accordance with the wiring diagram pro-
vided inside the control panel cover.
L
V
C
OW
OLTAGE
ONNECTIONS
The unit is designed to work as part of a fully communicating
HVAC system, utilizing a ComfortNet™ CTK04 thermostat,
ComfortNet compatible indoor unit, and up to four wires. Route
control wires through the low voltage port and terminate in ac-
cordance with the wiring diagram provided inside the control
panel cover.
Voltage Ports
Connect low voltage communication wires (1, 2) to low voltage
pigtail provided.
T
W
HERMOSTAT
IRING
NOTE:
A removable plug connector is provided with the control
to make thermostat wire connections. This plug may be removed,
wire connections made to the plug, and replaced. It is STRONGLY
recommended that you do not connect multiple wires into a single
terminal. Wire nuts are recommended to ensure one wire is used
for each terminal. Failure to do so may result in intermittent
operation.
Typical 18 AWG thermostat wire may be used to wire the system
components. However, communications reliability may be im-
proved by using a high quality, shielded, twisted pair cable for
the data transmission lines. In either case, 250 feet is the maxi-
mum length of wire between indoor unit and outdoor unit, or
between indoor unit and thermostat.
T
WO
Low voltage wiring consists of two wires between the indoor unit
and outdoor unit and four wires between the indoor unit and
thermostat. The required wires are data lines 1 and 2, "R" (24 VAC
hot) and "C" (24 VAC common).
S
TEP
The heat pump unit is shipped with a predetermined factory charge
level as shown below. For longer line sets greater than 15 feet,
add 0.6 ounces of refrigerant per foot. Refer to the following page
for the equivalent length of the elbow fittings.
NOTICE
LOW
HIGH
VOLTAGE
VOLTAGE
The following table shows refrigerant amounts for every 5 feet of
line.
15 (Factory Charge)
7
-W
O
, F
-W
IRE
UTDOOR
OUR
CTK04
1
2
R C
Thermostat
Compatible
1
2 R C
Air Handler
Integrated Control Module
Compatible AC/HP
1
2
R C
Integrated Control Module
System Wiring
1. C
R
C
ALCULATE
EFRIGERANT
T
R
=
OTAL
EFRIGERANT
F
C
+ (0.6
ACTORY
HARGE
OZ
A
L
S
).
OF
CTUAL
INE
ET
2-Ton
Actual Line Set
Length (ft.)
139
20
142
25
145
30
148
35
151
40
154
45
157
50
160
55
163
60
166
65
169
70
172
75
175
80
178
85
181
90
184
95
187
100
190
I
W
IRE
NDOOR
IRING
B
L
S
L
HARGE
ASED ON
INE
ET
ENGTH
./
. * A
F
FT
DDITIONAL
EET
Unit Tonnage
3-Ton
4-Ton
Total Refrigerant (Oz.)
139
160
142
163
145
166
148
169
151
172
154
175
157
178
160
181
163
184
166
187
169
190
172
193
175
196
178
199
181
202
184
205
187
208
190
211
5-Ton
237
240
243
246
249
252
255
258
261
264
267
270
273
276
279
282
285
288