AtmosAir FC-400 Installation, Operation And Maintenance Manual

AtmosAir FC-400 Installation, Operation And Maintenance Manual

Ionization generators

Advertisement

Quick Links

Installation, Operations and
Maintenance Guide
AtmosAir
FC-400 & FC-400 FM

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FC-400 and is the answer not in the manual?

Questions and answers

Summary of Contents for AtmosAir FC-400

  • Page 1 Installation, Operations and Maintenance Guide AtmosAir FC-400 & FC-400 FM...
  • Page 2: Product Overview

    Visibly Cleaner Air AtmosAir eliminates pollutants and restores air quality in commercial, industrial and residential buildings. When you choose AtmosAir, you’ll refresh your indoor environment with the same clean, pure air found only at the highest mountain elevations. Product Overview...
  • Page 3: Mechanical Installation

    Installation AtmosAir FC-400 series equipment can be mounted in a duct (FC-400 FM) or, air handler wall or in supply slot FC-400, using the faceplate mounting flange and its weather-strip gasket; or inside a plenum using a universal mounting bracket. The units operate best when located after all filters, coils, and fans.
  • Page 4: Electrical Installation

    Field-install a power plug outlet or junction box within 1.82m of the unit(s). Each FC-400 series unit is typically shipped with a 2.438m power cord with a field install pair of wire hot/neutral connector on one end and a quick disconnect plug on the other end. FC-400FM has a moisture-proof quick disconnect on the unit.
  • Page 5: Operation

    The FC-400 series is provided with an internal fuse and a spare fuse is provided. The local AtmosAir dealer can provide you with an annual service contract.
  • Page 6: Troubleshooting

    If power is reaching the unit and it was necessary next step is to determine whether there is a fault in the system or a tube. If all external sources of failure are eliminated, the system should be serviced by a qualified AtmosAir technician.
  • Page 7 Otherwise, replace the damaged tube, clean and smooth any mounting plate or end cap carbon tracking, and return the system to service. ~~DO NOT open the enclosure, as this will void any warranties. ~~ If the cause of failure cannot be determined, please contact AtmosAir for further help.
  • Page 8: Quick-Clean

    Tube Cleaning Instructions It may be beneficial to clean the tubes to improve performance, by removing dirt and grease from the tube and mesh where it impairs the ability to generate the plasma for ion creation. The tubes can be cleaned using an air compressor for a quick clean, or more thoroughly with cleaning solutions.
  • Page 9 AtmosAir’s unique and proven air purification process significantly reduces mold, controls the spread of bacteria and airborne viruses, and reduces airborne particles that evade normal filtration solutions.