& M5 Pre-filter ........... 1 unit Ref. FAE1-100 *Already assembled Power cable ........... 1 unit Ref. 0009417 (100V / 120V) 0009401 (230V) Manual ..........1 unit Unseal the filter Ref. 0023483 before the first use w w w.jbctools.com INSTRUCTION MANUAL Fume Extractor Ref. FAE1-B...
Page 3
w w w.jbctools.com Features Aspiration tubes for 1 workbench and up to 4 stands (1 work intake configuration) or for 2 workbenchs (2 work intakes configuration). Quick release levers for filter change Process screen Filter saturation indicator Green: Filter OK Yellow: ≤...
Page 4
1 work intake configuration assembly (default configuration) Flexible arm Ø50 Stand Ref. FAE070 Aspiration Duct Lenght: 1 m (39.37 in) Ref. FAE050 Ref. FAE060 To be assembled on For modular stands For compact stations your workbench with (From SD versions (From B versions the included clamp onwards)
Page 5
w w w.jbctools.com 2 work intakes configuration assembly (optional configuration) In this configuration aspiration at stand is not available, aspiration flow is set High. Note that in this configuration, suction force per intake is decreased when compared to 1 work intake configuration (see details on page 14).
Turning on the fume extractor Once the fume extractor is turned on, the display shows a similar screen as the following one and the filter saturation indicator is green if the carbon lifetime is higher than 20%. F i l t e r F i l t e r F l o w F l o w...
Page 7
w w w.jbctools.com Menu Interface Main menu parameters Original PIN: 0105 M a i n m e n u M a i n m e n u Exit 1 Reset 2 Unit U n i t U n i t 3 Port Continuous mode 2 Beep...
Page 8
Menu Interface Port menu 1 work intake configuration P o r t P o r t Program Ctm - 100% 2 Delay to stop 3 Pedal B a c k B a c k D e l a y t o s t o p D e l a y t o s t o p P e d a l P e d a l...
Page 9
w w w.jbctools.com Parameters Important: Power off any Station or Device connected to the fume extractor before modifying any parameter. Unit Parameter Description Enable/disable continuous aspiration. When enabled, fume extractor suction is activated. Aspiration remains active until continuous mode is Continuous mode disabled or the equipment is powered off.
Page 10
Port Parameter Description It sets the fume extractor aspiration flow. You can select between Preset and Custom aspiration programs. H (High), M (Medium) or L (Low) are the three Preset available options. Use Up and Down keys to switch between them while being on the main screen.
Page 11
w w w.jbctools.com Filter set Parameter Description It shows remaining activated carbon lifetime expressed in %. It is also Carbon life displayed on the main screen. When 0% is reached the system will show pop-up message STOP#1 to replace the filter. It shows saturation status of HEPA + carbon filter set, expressed in %.
Page 12
RJ12 station connections for Excellence range Allows connecting JBC Soldering Stations featuring a Robot port to the fume extractor in order to automatically activate the extraction when the tools are in use. An RJ12 direct cable is required (ref. 0019751).
Page 13
RJ12 station connections for Advanced range Allows connecting JBC Soldering Stations featuring a USB-B port to the fume extractor in order to automatically activate the extraction when the tools are in use. An USB A/B cable (ref. 0021042) and RJ12-USB A adapter (ref.
Page 14
Fume extractor configurations Some parameters, features and the performance vary depending on fume extractor configuration, see the following table: 230V 50/60Hz 1 work intake 2 work intakes Work aspiration intakes Stand aspiration intakes Not available 80 m3 / h (47.08 cfm) 60 m3 / h (35.31 cfm) Flow per work intake Preset aspiration programs...
w w w.jbctools.com Maintenance - Filter replacement - The unit notifies through both the display and the LED when filters need maintenance. - To replace the filters remove the cover by opening the quick release levers of the casing. - If the saturation indicator remains in red after changing the pre-filter, it means that H13 particle filter is already saturated and must be replaced too.
Page 16
Maintenance - Filter replacement Connect the filter tube to The filter has a given position. the quick coupling placed Make sure the filter ribs mate on the metal sheet with the corresponding slots. Quick Release Levers Adjustment - Turn clockwise to loosen and counterclockwise to tighten, in order to adjust the filter airtightness. Read safety guidelines to do the equipment maintenance safely.
Page 17
w w w.jbctools.com Safety Follow safety guidelines to prevent electric shock, injury, fire or explosion. - The equipment is only designed to filtrate the fumes generated by soldering. - Do not use the units for the filtration of combustible, explosive or corrosive gasses. Incorrect use may cause fire.
In order for the warranty to be valid, equipment must be returned, postage paid, to the dealer where it was purchased. Get 1 extra year JBC warranty by registering here: https://www.jbctools.com/productregistration/ within 30 days of purchase. This product should not be thrown in the garbage.
Need help?
Do you have a question about the FAE1-B and is the answer not in the manual?
Questions and answers