better together blue - bluePRO (ATEX - IECEx) use and maintenance booklet safety instructions...
Page 2
N° CN/CQM/QAR10.0003 performed by CQM - China Quality Mark Certification Group Co., Ltd. The manufacturer ZENIT ITALIA S.r.l. operates in accordance with Quality Control System procedures which comply with the UNI EN ISO 9001 standard, accredited by DNV with certificate No. CERT-00660-95-AQ-IND-SINCERT.
The images are indicative only and may not match the actual product. Details given here may differ from the actual product. Zenit reserves the right to modify the product without prior warning. For more information, consult the website www.zenit.com. TABLE OF CONTENT 1.
1.2 EQUIPMENT: EXPLANATION TO -EX APPROVAL The electrical pumps BLUE series are suitable for professional use, heavy duty with clean and dirty water. They have the types of protection “Ex ec” and “Ex h” and are suitable for gas group IIC.
Use and maintenance booklet - Safety instructions better together X: specific conditions of use The certificate number indicated on the nameplate is followed by an “X”. It means that the user must follow specific conditions of use described in this manual. 1.
2.USE AND MAINTENANCE INSTRUCTIONS 2.1 HOW TO IDENTIFY THE PRODUCT Ex ec nC h IIC T3 Gc IECEX EUT 16.YYYYX Modena - Made in Italy www.zenit.com 1. Product name 11. Rpm 2. Serial number 12. Minimum and maximum flow-rate 3. Year of manufacture 13.
Use and maintenance booklet - Safety instructions better together 2.3 ELECTRICAL FEATURES DR/DG blue 40/2 DR/DG blue 50/2 DR/DG blue 75/2 DR/DG blue 100/2 Pump type DR/DG bluePRO 40/2 DR/DG bluePRO 50/2 DR/DG bluePRO 75/2 DR/DG bluePRO 100/2 0.3 (50Hz) Rated power [kW] 0.37 (50/60Hz) 0.55 (50/60Hz)
Use and maintenance booklet - Safety instructions better together 2.4.3 With the joining foot (fig. 3) Designed for the horizontal outlet models. Fix the joining foot to the bottom of the tank first, using expansion plugs. Install the delivery pipe with the relative non-return valve and gate valve.
Use and maintenance booklet - Safety instructions better together 2.7 THERMAL PROTECTION “Ex ec nC” pumps are equipped with encapsulated thermal protection devices installed within the stator winding. These protection device interrupts the power supply in conditions of overheating of the motor when abnormal operation occurs. The user must protect the motor of Ex nC pumps (without thermal protector) by an overload protection (motor protection breaker) having rated or setting current equal to or below the value of the rated motor power supply current (In) (see also point 2.11).
The pump must be overhauled even if the pump appears normal during years operation. Especially, the pump may need to be overhauled earlier if it is used continuously. NOTE: To overhaul the pump, contact the dealer where it was purchased, or the ZENIT sales office in your area.
Use and maintenance booklet - Safety instructions better together 2.12 TROUBLESHOOTING GUIDE Problem Possible cause Solution No power supply Check power supply line. Check the cable connections and make sure that it’s not dama- Damaged or disconnected cable ged. Fuses blown Check fuses type and rating and replace them with correct ones.
Use and maintenance booklet - Safety instructions better together 2.14 OVERALL DIMENSIONS DR blue DR blue 40/2/G40V G 1¼” DR blue 50/2/G40V G 1¼” DR blue 75/2/G40V G 1¼” DR blue 100/2/G40V G 1¼” DR bluePRO DR bluePRO 50/2/G32V G 1¼” DR bluePRO 75/2/G32V G 1¼”...
Page 15
Use and maintenance booklet - Safety instructions better together GR bluePRO GR bluePRO 100/2/G40H G 1½” 90° 180° GR bluePRO 150/2/G40H G 1½” 90° 180° GR bluePRO 200/2/G40H G 1½” 90° 180° AP bluePRO AP bluePRO 100/2/G40H G 1½” 90° 180°...