Dell EMC PowerEdge C6420 Installation And Service Manual page 42

Hide thumbs Also See for EMC PowerEdge C6420:
Table of Contents

Advertisement

2. Push the blue retention clips inward to allow the heat sink to drop into place.
3. Using the Torx #T30 screwdriver, tighten the screws on the heat sink in the order below:
a. Partially tighten the first screw (approximately 3 turns).
b. Tighten the second screw completely.
c. Return to the first screw and tighten it completely.
If the PHM slips off the blue retention clips when the screws are partially tightened, follow these steps to secure the PHM:
a. Loosen both the heat sink screws completely.
b. Lower the PHM on to the blue retention clips, following the procedure described in step 2.
c. Secure the PHM to the system board, following the replacement instructions listed in this step above. 4.
NOTE:
The processor and heat sink module retention screws should not be tightened to more than 0.13 kgf-m (1.35
N.m or 12 in-lbf).
Figure 30. Installing a processor and heat sink module
Next steps
1.
Install the air
shroud.
2. Connect the fabric cable to the fabric processor.
3. Follow the procedure listed in
42
Installing and removing enclosure components
After working inside your
system.

Advertisement

Table of Contents
loading

Table of Contents