Liquiflo H Series Installation, Operation & Maintenance Manual page 27

Magnetic-drive gear pumps
Hide thumbs Also See for H Series:
Table of Contents

Advertisement

Liquiflo Installation, Operation & Maintenance Manual
16
Slide the inner magnet (11) onto the
drive shaft (20) until it contacts the
retaining ring in the inner groove.
NOTE: Install inner magnet with orientation as
described on Page 26.
17
Install the second retaining ring (28)
into the outer groove, as shown.
NOTE: Use a rubber mallet, as shown, to tap the
retaining ring into the outer groove. This will lock
the inner magnet assembly on the drive shaft.
_____________________________________________________________________________________
18
Turn the inner magnet (11) by hand to
ensure free rotation of the gears.
NOTE: During this check, the gears can be
viewed thru the ports of the pump (see photo).
_____________________________________________________________________________________
19
Verify that the containment can O-ring is installed (see
containment can (12) to the pump housing using six sets of bolts (18) and lockwashers (32).
This completes the Pump Cartridge assembly.
NOTE: Apply anti-seize compound to the bolts. Refer to Appendix 1 for the torque specifications of the fasteners.
When tightening the containment can bolts, use a star pattern torque sequence on the fasteners to ensure even
compression on the O-ring's surface. With Teflon O-rings, repeat this process several times, waiting between
retightening. This is necessary because the Teflon will cold flow and require a certain amount of time to properly
seat. Continue the process until the bolts no longer require retightening.
_____________________________________________________________________________________
Gears visible thru Port
Containment
Can
27
MAG-DRIVE Gear Pumps
Models H1-H9, 31-39 & 311 - MC
Inner
Magnet
Retaining
Ring
Step
13, Page 24); then attach the
Pump Cartridge

Advertisement

Table of Contents
loading