5.3

PUMP DISASSEMBLY

Follow the procedure below and refer to the drawings in Appendix 6.
_____________________________________________________________________________________

Cartridge Removal:

1
Remove the four front housing bolts (27)
from the pedestal (16).
_____________________________________________________________________________________
2
Carefully pull the Cartridge straight out.
CAUTION! Do not place hands
or fingers between Pedestal and
Pump Cartridge.
NOTE: Force must be applied to overcome the magnetic
attraction between the outer and inner magnets. (See Page
20 for information on the Pump Cartridge.)
_____________________________________________________________________________________
3
Remove six screws (18) and separate the containment can (12) from the front housing (8).
Discard the containment can O-ring (19).
_____________________________________________________________________________________
Front
Housing
Containment Can
15
MAG-DRIVE Gear Pumps
Models H1-H9, 31-39 & 311 - MC
Pedestal
Pinch Point