CoNNECTIoN To PoWER MAINS

THE UNIT MUST BE CoNNECTED To PoWER SUPPlY BY A QUAlIFIED ElECTRICIAN.
The ventilator is rated for connection to single-phase AC 220...240 V/50 Hz power mains using a power cable with a plug installed at the
factory.
WARNING!
The unit must not be connected through any type of speed regulators – thyristor, autotransformer, frequency, etc.
The ventilator must be connected to the stationary power supply via an integrated switch with a gap between the contacts at all poles
of at least 3 mm.
The unit is equipped with an electric motor, which has two fixed speeds. Switching from the first speed to the second is carried out only
by a standard pull cord switch.
MAINTAINING THE FACToRY CoNFIGURATIoN AND FoRM FACToR IS ABSolUTElY ESSENTIAl
To THE ElECTRICAl CoNNECTIoNS DIAGRAM SHAll RElIEVE THE MANUFACTURER FRoM
10
PoWER oFF THE PoWER SUPPlY PRIoR To ANY oPERATIoNS WITH THE UNIT.
THE RATED ElECTRICAl PARAMETERS oF THE UNIT ARE GIVEN oN THE
220...240 V 50 Hz
All THE CoMPoNENTS oF THE UNIT ARE ITS INTEGRAl PARTS.
FoR THE PRoPER AND CoNSISTENT FUNCTIoNING oF THE UNIT.
ANY UNAUTHoRISED AlTERATIoNS To THE UNIT FoRM FACToR oR FAIlURE To ADHERE
lIABIlITY FoR ANY RESUlTING MAlFUNCTIoNS AND VoID THE UNIT WARRANTY.
MANUFACTURER'S lABEl.
ON/OFF
Speed switch
(speed I-II)
Solo RA1-35(A)-9R
www.ventilation-system.com