Vents Solo RA1-35A-9 P User Manual

Vents Solo RA1-35A-9 P User Manual

Single-room reversible energy recovery ventilator
Hide thumbs Also See for Solo RA1-35A-9 P:

Advertisement

USER'S MANUAL
Solo RA1-35А-9 P
Solo RA1-35-9 P
Single-room reversible energy recovery ventilator

Advertisement

Table of Contents
loading

Summary of Contents for Vents Solo RA1-35A-9 P

  • Page 1 USER’S MANUAL Solo RA1-35А-9 P Solo RA1-35-9 P Single-room reversible energy recovery ventilator...
  • Page 2: Table Of Contents

    Solo RA1-35(A)-9R CoNTENTS Safety requirements ..................................2 Purpose ........................................ 4 Delivery set ......................................4 Designation key ....................................4 Technical data ....................................5 Design and operating principle ............................6 Installation and set-up................................7 Connection to power mains and control ........................8 Technical maintenance ................................
  • Page 3 • Do not change the power cable length at your own discretion. Do not bend the • Do not lay the power cable of the unit in power cable. Avoid damaging the power close proximity to heating equipment. cable. Do not put any foreign objects on the power cable.
  • Page 4: Purpose

    Solo RA1-35(A)-9R PURPoSE The ventilator is designed to ensure continuous mechanical air exchange in flats, cottages, hotels, cafés and other domestic and public premises. The ventilator is equipped with a heat exchanger that enables supply of fresh filtered air heated by means of extract air heat energy recovery.
  • Page 5: Technical Data

    TECHNICAl DATA The unit is designed for indoor application with the ambient temperature ranging from -15 °C up to +50 °C and relative humidity up to 97 %. The ventilator is rated as a class II electric appliance. Ingress protection rating against access to hazardous parts and water ingress is IP24. The unit design is constantly being improved, thus some models may be different from those described in this manual.
  • Page 6: Design And Operating Principle

    Solo RA1-35(A)-9R DESIGN AND oPERATING PRINCIPlE The ventilator consists of an air duct, a ventilation unit and an outer ventilation hood. Two filters, a heat exchanger, a distance ring and two air flow rectifiers are installed in the air duct. The air filters are designed to purify supply air and prevent foreign object ingress into the heat exchanger and the fan.
  • Page 7: Installation And Set-Up

    INSTAllATIoN AND SET-UP READ THE USER'S MANUAl BEFoRE INSTAllING THE UNIT Do NoT BloCK THE AIR DUCT oF THE INSTAllED VENTIlAToR WITH DUST ACCUMUlATING MATERIAlS, SUCH AS CURTAINS, CloTH SHUTTERS, ETC. AS IT PREVENTS AIR CIRCUlATIoN IN THE RooM. 1. Prepare a round core hole in the outer wall. The hole size is shown in the figure below. min 500 Ø...
  • Page 8: Connection To Power Mains And Control

    Solo RA1-35(A)-9R 4. Use a screwdriver to take off the front side of the ventilation unit. 5. Attach the mounting plate and mark the places for the dowels with a pencil or marker. Drill the holes and insert the dowels. Then mount the mounting plate on the wall and install the rear part of the ventilation unit in the duct.
  • Page 9: Technical Maintenance

    TECHNICAl MAINTENANCE DISCoNNECT THE UNIT FRoM PoWER SUPPlY BEFoRE ANY MAINTENANCE oPERATIoNS! Maintenance of the ventilator means regular cleaning of the ventilator surfaces of dust and cleaning and replacement of the filters. Accessing the main units for servicing and maintenance as follows. Remove the front side of the ventilation unit by unscrewing the self-tapping screw.
  • Page 10: Storage And Transportation Regulations

    Solo RA1-35(A)-9R PoSSIBlE REASoNS AND TRoUBlESHooTING Problem Possible reasons Troubleshooting Make sure the power supply line is connected correctly, No power supply. otherwise troubleshoot the connection error. When switching on the ventilator the fan does not Turn the ventilator off. Troubleshoot the motor jam start.
  • Page 11: Manufacturer's Warranty

    MANUFACTURER’S WARRANTY The product is in compliance with EU norms and standards on low voltage guidelines and electromagnetic compatibility. We hereby declare that the product complies with the provisions of Electromagnetic Council Directive 2014/30/EU, Low Voltage Directive 2014/35/ EU and CE-marking Directive 93/68/EEC. This certificate is issued following test carried out on samples of the product referred to above. The manufacturer hereby warrants normal operation of the unit for 24 months after the retail sale date provided the user's observance of the transportation, storage, installation, and operation regulations.
  • Page 12 Solo RA1-35(A)-9R www.ventilation-system.com...
  • Page 13 www.ventilation-system.com...
  • Page 14 Solo RA1-35(A)-9R www.ventilation-system.com...
  • Page 15: Certificate Of Acceptance

    CERTIFICATE oF ACCEPTANCE Unit Type Single-room reversible energy recovery ventilator Model Solo RA1- ___________________ Serial Number Manufacture Date Quality Inspector’s Stamp SEllER INFoRMATIoN Seller Address Phone Number E-mail Purchase Date This is to certify acceptance of the complete unit delivery with the user’s manual. The warranty terms are acknowledged and accepted.