Installation And Set-Up - Vents Solo RA1-35A-9 R User Manual

Single-room reversible energy recovery ventilator
Hide thumbs Also See for Solo RA1-35A-9 R:
Table of Contents

Advertisement

INSTAllATIoN AND SET-UP

1. Prepare a round core hole in the outer wall. The hole size is shown in the figure below.
2. Insert the air duct in the wall. For ease of installation use the foam wedges included in the delivery set. The air duct end must protrude
for the distance A that enables installation of the outer ventilation hood. The distance A is stated in the mounting instruction for the outer
ventilation hood.
Foam wedge
3. Install the assembled regenerator into the air duct.
8
READ THE USER'S MANUAl BEFoRE INSTAllING THE UNIT.
Do NoT BloCK THE AIR DUCT oF THE INSTAllED VENTIlAToR WITH DUST
ACCUMUlATING MATERIAlS, SUCH AS CURTAINS, CloTH SHUTTERS, ETC.
AS IT PREVENTS AIR CIRCUlATIoN IN THE RooM.
min 500
Ø 120
min 500
Fill the gaps between the wall
and the hole with a
mounting foam.
A
A
A
While mounting the air duct be sure to provide the minimum slope
3 mm downwards from outside.
The air duct can be cut by calculating preliminary the required length
or after fixing the air duct on the wall (in this case, it is necessary to
have access to the outside part of the wall).
min 3 mm
Solo RA1-35(A)-9R
A-A
www.ventilation-system.com

Advertisement

Table of Contents
loading

This manual is also suitable for:

Solo ra1-35-9 r

Table of Contents