Vents Solo RA1-35-9 R User Manual

Vents Solo RA1-35-9 R User Manual

Single-room reversible energy recovery ventilator
Hide thumbs Also See for Solo RA1-35-9 R:

Advertisement

USER'S MANUAL
Solo RA1-35-9 R
Solo RA1-35-9 R V.2
Single-room reversible energy recovery ventilator

Advertisement

Table of Contents
loading

Summary of Contents for Vents Solo RA1-35-9 R

  • Page 1 USER’S MANUAL Solo RA1-35-9 R Solo RA1-35-9 R V.2 Single-room reversible energy recovery ventilator...
  • Page 2: Table Of Contents

    Warranty card ....................................15 This user’s manual is a main operating document intended for technical, maintenance, and operating staff. The manual contains information about purpose, technical details, operating principle, design, and installation of the Solo RA1-35-9 R (V.2) unit and all its modifications.
  • Page 3 • Do not close or block the intake or extract vents in order to ensure the efficient air flow. • Do not sit on the unit and do not put objects on it. • The information in this user’s manual was correct at the time of the document’s preparation.
  • Page 4: Purpose

    Solo RA1-35-9 R (V.2) PURPOSE The ventilator is designed to ensure continuous mechanical air exchange in flats, cottages, hotels, cafés and other domestic and public premises. The ventilator is equipped with a regenerator that enables supply of fresh filtered air heated by means of extract air heat energy recovery.
  • Page 5: Technical Data

    TECHNICAL DATA The temperature in the room where the indoor unit of the ventilator is installed must be in the range from +1 ˚C to +40 ˚C with relative humidity up to 65 % (no condensation build-up). If the conditions for using the ventilator are beyond the specified limits, turn off the ventilator.
  • Page 6: Design And Functioning

    Solo RA1-35-9 R (V.2) DESIGN AND FUNCTIONING The ventilator consists of an air duct, a ventilation unit and an outer ventilation hood. Two filters, a regenerator, a distance ring and two air flow rectifiers are installed in the air duct.
  • Page 7: Mounting And Set-Up

    MOUNTING AND SET-UP READ THE USER'S MANUAL BEFORE INSTALLING THE UNIT. DO NOT BLOCK THE AIR DUCT OF THE INSTALLED VENTILATOR WITH DUST ACCUMULATING MATERIALS, SUCH AS CURTAINS, CLOTH SHUTTERS, ETC. AS IT PREVENTS AIR CIRCULATION IN THE ROOM. 1. Prepare a round core hole in the outer wall. The hole size is shown in the figure below. min 300 Ø...
  • Page 8 Solo RA1-35-9 R (V.2) 4. Use a screwdriver to take off the front side of the ventilation unit. 5. Attach the mounting plate and mark the places for the dowels with a pencil or marker. Drill the holes and insert the dowels. Then mount the mounting plate on the wall and install the rear part of the ventilation unit in the duct.
  • Page 9: Connection To Power Mains

    The unit is equipped with an electric motor, which has two fixed speeds. Controlling the Solo RA1-35-9 R ventilator using a pull cord switch The ventilator is connected to power mains using a cord with a plug with a switch on the wire.
  • Page 10 Solo RA1-35-9 R (V.2) Controlling the Solo RA1-35-9 R V.2 ventilator using the remote control The ventilator is connected to power mains using a cord with a plug. The function of the remote control buttons is shown in the figure below.
  • Page 11: Technical Maintenance

    TECHNICAL MAINTENANCE DISCONNECT THE UNIT FROM POWER SUPPLY BEFORE ANY MAINTENANCE OPERATIONS! ENSURE THAT THE UNIT IS SWITCHED OFF FROM THE SUPPLY MAINS BEFORE REMOVING THE GUARD. Maintenance of the ventilator means regular cleaning of the ventilator surfaces of dust and cleaning and replacement of the filters. Accessing the main units for servicing and maintenance is as follows.
  • Page 12 Solo RA1-35-9 R (V.2) 3. Replacing the battery in the remote control (when needed). No response of the ventilator for pressing the remote control buttons indicates the need to replace the battery. The battery type is CR2025. To replace the battery of the remote control, remove the battery holder with a battery.
  • Page 13: Storage And Transportation Regulations

    STORAGE AND TRANSPORTATION REGULATIONS • Store the unit in the manufacturer’s original packaging box in a dry closed ventilated premise with temperature range from +5 °C to + 40 °C and relative humidity up to 70 %. • Storage environment must not contain aggressive vapors and chemical mixtures provoking corrosion, insulation, and sealing deformation.
  • Page 14: Manufacturer's Warranty

    Solo RA1-35-9 R (V.2) MANUFACTURER’S WARRANTY The product is in compliance with EU norms and standards on low voltage guidelines and electromagnetic compatibility. We hereby declare that the product complies with the provisions of Electromagnetic Compatibility (EMC) Directive 2014/30/EU of the European Parliament and of the Council, Low Voltage Directive (LVD) 2014/35/EU of the European Parliament and of the Council and CE-marking Council Directive 93/68/EEC.
  • Page 15: Certificate Of Acceptance

    CERTIFICATE OF ACCEPTANCE Unit Type Single-room reversible energy recovery ventilator Model Solo _________________ Serial Number Manufacture Date Quality Inspector’s Stamp SELLER INFORMATION Seller Address Phone Number E-mail Purchase Date This is to certify acceptance of the complete unit delivery with the user’s manual. The warranty terms are acknowledged and accepted.
  • Page 16 V132EN-08...

This manual is also suitable for:

Solo ra1-35-9 r v.2

Table of Contents