CMD1 0822 --> 01-R-01-02
DATA DEAD
STA1 0800
Dev0 MSG #1534.
CMD1 1822 --> 03-R-01-02
DATA 0005
STA1 1800
Command 'S' displays the current SMT command and data buffer addresses.
This example shows the necessary steps to enable the BC and both RT's in both devices and begin
transmitting from both BC's using command 'a' and 'A'. Both devices are only available with a -2F card
so with a -1F card there's no need to enter the upper case commands and no Dev1 messages will be
presented in the output shown below. Notice some messages are from Dev0 and some are from Dev1.
>> b
>c
>k (RTMT Demo)
>t (Traffic Enabled)
>B
>C
>K
RTMT Demo
>a
>A (this will be seen much later inter-mixed in the messages below)
With a -2F card a mixed of messages from Dev0 and Dev1 are displayed.
Dev0 MSG #0283.
CMD1 182A --> 03-R-01-10
CMD2 0C2A --> 01-T-01-10
STA1 0800
DATA BBBB
STA2 1800
Dev1 MSG #0284.
CMD1 1822 --> 03-R-01-02
DATA 0005
STA1 1800
Dev1 MSG #0285.
CMD1 182A --> 03-R-01-10
CMD2 0C2A --> 01-T-01-10
STA1 0800
DATA BBBB
STA2 1800
Dev0 MSG #0286.
CMD1 1822 --> 03-R-01-02
DATA 0005
STA1 1800
Dev0 MSG #0287.
CMD1 182A --> 03-R-01-10
CMD2 0C2A --> 01-T-01-10
STA1 0800
BEEF
TIME = 00098222us
0002
TIME = 00130428us
0202
1414
0404
0909
1010
TIME = 00090538us
0002
TIME = 00090842us
0202
1414
0404
0909
1010
TIME = 00099052us
0002
TIME = 00099356us
Holt Integrated Circuits
20
BUS A
TYPE0: BC to RT
BUS A
TYPE2: RT to RT
0505
0606
0707
0808
BUS A
TYPE0: BC to RT
BUS A
TYPE2: RT to RT
0505
0606
0707
0808
BUS A
TYPE0: BC to RT
BUS A
TYPE2: RT to RT

Advertisement