Operation Indicator; Dip Switch Settings - Optex VVS-1 Operation Manual

Table of Contents

Advertisement

Installation
Place the housing cover.
STEP 14
* Check that the housing cover and wiring are not interfering.
If wiring is to be exposed, break the knockout.
WARNING
■ Do not use without the housing cover.
■ When using the cable knockout, install on the indoors or use the
rain cover (separately available) otherwise electric shock or
breakdown of the sensor may occur.
Adjustments
App password reset switch
Use this switch when resetting the app's
password to the default values (0000).
Push the switch for 2 seconds after
confirming that the product is in the
stand-by status.
(See [Operation indicator])
Cross traffic
Warm-up
Stand-by
Green
Green
glimmering
glimmering
Sensor failure
The operation status of the header sensor is displayed on the
Fast green
operation indicator of the header sensor. For details, refer to
blinking
the operation manual of the header sensor.
This product links with the smart device app "VVS eTracker", and the app can show
the contribution ratio to the environment compared to conventional sensors.
For details, refer to VVS eTracker User guide.
Danger of fire and electric shock
Use this switch when resetting the IP address to the default
values (192.168.0.249).
Push the switch for 2 seconds after confirming that the
product is in the stand-by status.
When the reset is confirmed, the IP address reset indicator
goes on from the blinking status.

Operation indicator

During connecting
Detection
to the app
cancel
Blue
Slow green & blue
Red
blinking
* Operation indicator is turned off after completing.
Smart device app
Main body
Housing cover
IP address reset switch
IP address reset indicator
Dipswitch 1 : Warm-up output
App password
reset
The Activation output during warming up (approx. 30sec.)
when just after turning on the power and changing the
Fast green &
web setting is adjustable. When setting to "OFF", the door
blue blinking *
becomes the closed state, and when setting to "ON", the
door becomes the opened state. Normally, set to "ON".
Dipswitch 3 : Activation output
Dipswitch 3 is for the Activation output to the door
controller.
*Dipswitch 2, 4 to 8 is not used.
- 5 -
Knockout
LAN port
Perform the Web setting
through LAN connection.
For the setting method, see
the attached Web setting
manual.
Dipswitch settings
OFF
ON
1
1
N.O.
N.C.
3
3

Advertisement