Area settings

STEP 1
Click [Admin] on the login screen
and enter the password
(default setting: admin). After
entering the password, click
[Login].
STEP 3
Set the following each item and press the application button below.
Door position
Drag and drop the
and the
on the camera image to specify the
door opening width.
Installation height
Set the height of the sensor installation
suited to the installation environment.
Sensitivity
Adjust the detection sensitivity fitting
for the installation environment.
Normally, set to [Standard].
Human body detection size
Adjust the human body detection size
suited to the installation environment.
Normally, set to [Standard].
Immunity
Unnecessary openings due to
following conditions may be reduced
by selecting an object(s). In normal
cases it can be disabled.
*When the cursor is moved over to
on the Web screen, the explanation is shown.
*As for other setting items and the detailed setting method, confirm the explanation on the web screen.

Password settings

* Windows is a registered trademarks of Microsoft Corporation in the United States and/or other countries.
marks
Adjust the Activation output timing fitting for the installation environment. Specifying a "Fast" value
speeds up the Activation output timing, ensuring safety for rushing in, while energy-saving
efficiency gets worse as Activation output is made earlier for a slow approach. Specifying a "Slow"
value speeds down the Activation output timing, ensuring higher energy-saving efficiency, while
safety for a quick approach such as rushing in gets worse.
Manufacturer
OPTEX CO., LTD.
5-8-12 Ogoto Otsu 520-0101, Japan
TEL.: +81(0)77 579 8700
WEBSITE: www.optex.net
North and South America Subsidiary
OPTEX INCORPORATED
18730 S. Wilmington Avenue, Suite 100 Rancho
Dominguez CA 90220 U.S.A
TEL.: +1-800-877-6656
WEBSITE: www.ot-inc.com
STEP 2
Click [Area] from the upper menu.
Activation output timing
User Password Settings
You can change the password for user login.
Administrator password settings
The administrator password can be changed. Make sure to change the
password from the default setting by installer from the information security
point of view. Without the initial change, there is a possibility that unspecified
users may be able to change the settings and it may result in serious
accidents. Make sure to keep the password somewhere safe.
FAX.: +81(0)77 579 7030
FAX.: +1(310)898-1098
- (2) -
eTracker area
Drag and drop the
on the camera image to specify the
detection area range configured (or to
be configured) for the existing
automatic door sensor.
* eTracker is a unique indicator that
shows the contribution rate to the
environment compared with the
conventional automatic door sensor,
and it can numerically indicate the
effect of the installation of this device.
To view eTracker, install the
application dedicated to smart devices,
"VVS eTracker", on your device.
Human recognition area
Adjust the human recognition area
suited to the installation environment.
In normal case, specify the setting so
that the area should cover the entire
camera image. On the image, the
yellow line is displayed.
European Subsidiary
OPTEX Technologies B.V.
Henricuskade 17, 2497 NB The Hague, The Netherlands
TEL.: +31(0)70 419 41 00
FAX.: +31(0)70 317 73 21
E-MAIL: info@optex.eu
WEBSITE: www.optex.eu
East coast office
8510 McAlpines Park Drive, Suite 108
Charlotte, NC 28211 U.S.A.
TEL.: +1-800-877-6656
FAX.: +1(704)365-0818
WEBSITE: www.ot-inc.com
and the
marks

Advertisement

Table of Contents
loading

Table of Contents