Setup Cycle Screen - Desoutter ESP-CA 230 Original Instructions Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 4

5.3. SETUP CYCLE screen

To progress to the second screen, push MENU
again.
1
SETUP CYCLE
SCREWS
REJECTS
3
2
UNSCREW
NEW PR
YES
NO
Legend
1
SETUP CYCLE screen
You can modify the cycle parameters:
-
Number of screws
-
Rejected screws
-
Min and Max Screwing Time
-
Unscrewing
-
New program contact
-
Free cycle or Sequence
5.3.1. SCREWS
Number of screws in each Program, from 1 to
99.
5.3.2. REJECT
Number of rejected screws allowed in each
single cycle.
Tightening whose result is NOK (Not OK - see
below) may or may not be repeated if it has
been set as rejected or zero.
You can set up to 9 rejected tightening.
PR
4%
Soft
Cycle
Torque
Joint
ScrNOK
ScrOK
CycleOK
Legend
1
"OVER" message
If the quantity of rejected screws is exceeded,
the message "OVER" appears on the main
screen and the screwdriver is disabled.
To start again, push ESC or RESET contact from
external signal.
If the message "OVER" appears during a
sequence:
● To reset a single cycle : push ESC or RESET
contact for 1 sec. from external signal.
● To reset the sequence: push ESC or RESET
contact for 5 secs. from external signal until
the beginning of a new cycle.
05/2020
PR 1
MIN TIME
MAX TIME
0.3
2.5
PR CYCLE
SEQUENCE
FREE
________
1
SCREWS
OVER
0/5
1/1
Done/Set
Reject
CycleNOK
END
5.3.3. MIN TIME
Time between the lever pressed and the torque
reached.
If torque is reached before the minimum time
set, an error signal is sent, and the tightening is
identified as a NOK.
This happens typically when operator tightens
the same screw twice.
5.3.4. MAX TIME
Time between the lever pressed and the
maximum acceptable rundown time.
No torque signal is generated.
After max. time is reached, an error signal is
sent, identified as a NOK tightening.
This identifies possible stripped screws.
NOK
OK
0
t1
Legend
t
Time
t1 Min time
t2 Max time
5.3.5. UNSCREW
If you select YES the reverse function of your
screwdriver is active, i.e. you can unscrew as
usual whenever you wish.
If you select NO the reverse function of your
screwdriver is not active (you can never
unscrew).
If you select NOK the reverse function of your
screwdriver will be active only after a NOK
tightening signal.
5.3.6. NEW PR
If YES is selected, at the end of the Program
cycle you must close the contact New Cycle (pin
#4) to continue.
If NO, signal will stay on until the start of the
screwdriver for the next cycle.
6159932380
Issue no: 05
NOK
t(sec)
t2
11 / 296