RQYQ8PY1B
RQYQ10PY1B
RQYQ12PY1B
RQYQ14PY1B
RQYQ16PY1B
CONTENTS
1. FIRST OF ALL ......................................................................... 1
1-1 Safety precautions ........................................................... 1
1-2 Special notice of product ................................................. 2
1-3 Disposal requirements ..................................................... 2
2. INTRODUCTION...................................................................... 2
2-1 Combination..................................................................... 2
2-2 Standard supplied accessories ........................................ 3
2-3 Option accessory ............................................................. 3
2-4 Technical and Electrical specifications ............................ 3
2-5 Main components ............................................................ 3
2-6 Installation Process.......................................................... 3
3. SELECTION OF LOCATION ................................................... 4
4. INSPECTING AND HANDLING THE UNIT ............................. 4
5. PLACING THE UNIT................................................................ 4
6. REFRIGERANT PIPING .......................................................... 5
branching kit .................................................................... 5
6-3 Pipe connection ............................................................... 5
6-4 Connecting the refrigerant piping..................................... 5
6-5 Example of connection .................................................... 8
7. FIELD WIRING ...................................................................... 10
7-3 Leading wire Procedure ................................................. 10
7-5 Power Wiring Connection Procedure............................. 11
7-6 Procedure for Wiring Inside Units .................................. 12
8. AIR TIGHT TEST AND VACUUM DRYING ........................... 12
8-1 Preparations .................................................................. 12
9. PIPE INSULATION ................................................................ 13
CONDITIONS ........................................................................ 13
CHECK OPERATION ............................................................ 13
11-1 Before working............................................................... 13
operation........................................................................ 15
12. ONSITE SETTINGS............................................................... 20
12-1 Onsite Settings With the Power Off ............................... 20
12-2 Onsite Settings With the Power On ............................... 20
13. TEST RUN ............................................................................. 20
13-1 Before test run ............................................................... 20
13-2 Test Run ........................................................................ 20
13-3 Checks After Test Run................................................... 20
14. CAUTION FOR REFRIGERANT LEAKS ............................... 20
1.

FIRST OF ALL

• This document is an installation manual for the Daikin "VRVIII-Q"
Series VRV Inverter. Before installing the unit, read this manual
thoroughly, and following the instructions contained in it. After
installation, do a test run to make sure the unit runs properly, and
then explain how to operate and take care of the unit to the cus-
tomer, using the operation manual.
• Lastly, make sure the customer keeps this manual, along with the
operation manual, in a safe place.
• This manual does not describe how to install the indoor unit.
Refer to the installation manual included with the indoor unit for that.

1-1 Safety precautions

Please read these "Safety precautions" carefully before installing air
conditioning unit and be sure to install it correctly.
After completing installation, conduct a trial operation to check for
faults and explain to the customer how to operate the air conditioner
and take care of it with the aid of the operation manual. Ask the cus-
tomer to store the installation manual along with the operation man-
ual for future reference.
This air conditioner comes under the term "appliances not
accessible to the general public".
1
RQYQ18PY1B
RQYQ28PY1B
RQYQ38PY1B
RQYQ20PY1B
RQYQ30PY1B
RQYQ40PY1B
RQYQ22PY1B
RQYQ32PY1B
RQYQ42PY1B
RQYQ24PY1B
RQYQ34PY1B
RQYQ44PY1B
RQYQ26PY1B
RQYQ36PY1B
RQYQ46PY1B
RQYQ48PY1B
VRVIII System air conditioner
VRVIII-Q Series
Meaning of WARNING and CAUTION notices
WARNING..... Failure to follow these instructions properly may
result in personal injury or loss of life.
CAUTION...... Failure to observe these instructions properly
may result in property damage or personal injury,
which may be serious depending on the circum-
stances.
WARNING
• Ask your dealer or qualified personnel to carry out installation
work.
Do not attempt to install the air conditioner yourself. Improper
installation may result in water leakage, electric shocks or fire.
• Install the air conditioner in accordance with the instructions in
this installation manual.
Improper installation may result in water leakage, electric shocks
or fire.
• When installing the unit in a small room, take measures against to
keep refrigerant concentration from exceeding allowable safety
limits in the event of refrigerant leakage.
Contact the place of purchase for more information. Excessive
refrigerant in a closed ambient can lead to oxygen deficiency.
• Be sure to use only the specified accessories and parts for instal-
lation work.
Failure to use the specified parts may result in the unit falling,
water leakage, electric shocks or fire.
• Install the air conditioner on a foundation strong enough to with-
stand the weight of the unit.
A foundation of insufficient strength may result in the equipment
falling and causing injury.
• Carry out the specified installation work after taking into account
strong winds, typhoons or earthquakes.
Failure to do so during installation work may result in the unit fall-
ing and causing accidents.
• Make sure that a separate power supply circuit is provided for this
unit and that all electrical work is carried out by qualified personnel
according to local laws and regulations and this installation manual.
An insufficient power supply capacity or improper electrical con-
struction may lead to electric shocks or fire.
• Make sure that all wiring is secured, the specified wires are used,
and that there is no strain on the terminal connections or wires.
Improper connections or securing of wires may result in abnormal
heat build-up or fire.
• When wiring the power supply and connecting the remote control-
ler wiring and transmission wiring, position the wires so that the
EL.COMPO.BOX lid can be securely fastened.
Improper positioning of the EL.COMPO.BOX lid may result in
electric shocks, fire or the terminals overheating.
• If refrigerant gas leaks during installation, ventilate the area
immediately.
Toxic gas may be produced if the refrigerant comes into contact
with fire.
• After completing installation, check for refrigerant gas leakage.
Toxic gas may be produced if the refrigerant gas leaks into the
room and comes into contact with a source of fire, such as a fan
heater, stove or cooker.
• Do not directly touch refrigerant that has leaked from refrigerant
pipes or other areas, as there is a danger of frostbite.
• Be sure to switch off the unit before touching any electrical parts.
• Do not allow children to climb on the outdoor unit and avoid plac-
ing objects on the unit.
Injury may result if the unit becomes loose and falls.
• Be sure to earth the air conditioner.
Do not earth the unit to a utility pipe, lightning conductor or
telephone earth lead. Imperfect earthing may result in
electric shocks or fire.
A high surge current from lightning or other sources may cause
damage to the air conditioner.
• Be sure to install an earth leakage breaker.
Failure to install an earth leakage breaker may result in electric
shocks or fire.
CAUTION
• While following the instructions in this installation manual,
install drain piping to ensure proper drainage and insulate pip-
ing to prevent condensation.
Improper drain piping may result in indoor water leakage and
property damage.
Installation