Download Print this page
La Gard ComboGard Pro 39E Setup Instructions

La Gard ComboGard Pro 39E Setup Instructions

Electronic combination lock

Advertisement

Quick Links

ComboGard Pro locks can either be configured using the ComboGard Pro Setup software or through a series of keypad commands.
This document will cover configuring the lock using both methods.
The ComboGard Pro Lock has three states of operation: Factory
Default, Manual Setup, and Active. ComboGard Pro locks are
shipped from LA GARD in Factory Default state without Users or
features enabled.
Factory Default: The Lock must be in the Factory Default state
to be programmed by the PC software.
Factory mode functions as follows:
• 1 key – When pressed, will open the Lock.
• 0 key – When pressed, prompts the ComboGard Pro Setup
software to send the configuration settings to the Lock.
OR if pressed and held, places the Lock into Manual Setup.
• All other keys perform no function.
Manual Setup: The Lock can be configured using the
keypad only.
Active: To activate the Lock and freeze the configuration, the
Manager combination MUST be changed.
PROGRAMMABLE LOCK FEATURES
MODES (Multiple Modes may be selected.)
• Silent Alarm (Alarm Box Required - P/N 2789NC)
If enabled, this option will send a signal to an outside alarm
system through the LA GARD Alarm Box.
• Dual Mode
If enabled, two combinations will be required to operate
the Lock.
The Manager and one additional User must be active.
• Time Delay Override
If enabled, User 9 can override delay period.
User 9 must be active.
EXTERNAL SIGNALS (Alarm Box Required - P/N 2789NC. Only
one External Signal type may be selected.)
An external input signal to the Alarm Box will either disable the
Lock from opening, override the time delay, or enable the remote
override depending on the selection programmed for External
Signals.
• External Signal disables Lock opening with valid combination.
• OR External Signal overrides Time Delay. (This option is ONLY
available if enabled using Setup software.)
• OR External Signal enables the Remote Override. (This option
is ONLY available if enabled using Setup software, and with
Lock code level 39E v1.09 or higher.)
(P/N) 731.018 Rev H 12/14 • © copyright 2008-2014
COMBOGARDPRO
39E Electronic Combination Lock
SETUP INSTRUCTIONS
TIME DELAY
• Delay Period 1 - 99 minutes
• Open Period 1 - 19 minutes
NOTE: If the Time Delay On is not selected, then this feature is
inactive. This feature may be enabled later. (Refer to Manager
Instructions 732.018.)
COMBINATION LENGTH
A combination length from six (6) to nine (9) digits may be
selected.
NOTE: To maintain the VdS Class 2 and EN 1300 Class B
certification when the duress alarm feature is used, a combination
length of 7 digits or longer must be selected.
LOCK USERS
Manager
• Open Lock
• Change Combination
• Enable/Disable Users
• Delete Users
• Set Time Delay Values
• Audit Lock
Up to 9 Users
• Open Lock
• Change Combination
STANDARD LOCK FEATURES
Wrong Try Penalty
• Entry of four (4) consecutive invalid combinations initiates a five
(5) minute delay penalty.
Lock responses during the penalty period are as follows:
- The LED will flash every ten (10) seconds.
- If any key is pressed, the Lock will flash the LED and beep
three times.
• Once the penalty period has ended, two (2) consecutive invalid
combinations will initiate another five (5) minute penalty period.
Low Battery Warning
• Repeated audio/visual signals (LED flashes/beeps) during Lock
opening indicate the battery is low and should be
replaced immediately.
• If the battery level becomes too low to safely operate the Lock,
pressing any key will initiate the low battery warning.
The battery must be replaced before the Lock will operate.
Audit Records
• Lock records the last 63 events in non-volatile memory.
• Audit file cannot be deleted from the Lock.
• Only the Manager can audit the Lock.
• ComboGard Pro auditing software and an Interface Adapter are
required to retrieve a Lock audit.
Kaba Mas LLC
page 1 of 11

Advertisement

loading

Summary of Contents for La Gard ComboGard Pro 39E

  • Page 1 TIME DELAY Default, Manual Setup, and Active. ComboGard Pro locks are • Delay Period 1 - 99 minutes shipped from LA GARD in Factory Default state without Users or • Open Period 1 - 19 minutes features enabled. NOTE: If the Time Delay On is not selected, then this feature is Factory Default: The Lock must be in the Factory Default state inactive.
  • Page 2: Lock Operating Conventions

    4. Select the LA GARD CGP menu item. 5. Select the ComboGard Pro Setup icon. Start -> Programs -> LA GARD -> LA GARD CGP -> ComboGard Pro Setup (P/N) 731.018 Rev H 12/14 • © copyright 2008-2014 Kaba Mas LLC...
  • Page 3 Plug the USB or Serial Interface Adapter into an available USB port on the PC. If using a USB Adapter, the list of ports will be updated to reflect the new device. The LA GARD USB Interface Adapter can be identified in the list as USB Serial Adapter.
  • Page 4 Select by placing a check mark in the desired operational Mode: Silent Alarm, External Signals, and Time Delay. Multiple modes can be selected. Silent Alarm: If selected, a LA GARD alarm box will be required to use this feature. Dual Mode: If selected, two combinations are required to operate the lock. At least one additional User with combination must be installed.
  • Page 5 Time Delay Override: If selected, User 9 must be installed to use this option. The software will automatically install User 9 without combination (Figure 5). The Manager can choose to enable the w/Combination option or enroll User 9 through the keypad later. (Refer to Manager Instructions 732.018.) When selected, User 9 is automatically installed without Combination.
  • Page 6 Select Time Delay: The Delay and Open Periods may be set up in this window. Enable feature by placing a check mark in the Time Delay On box. Then enter the desired time period in the text box or use the up and down arrows to select the time periods. Example: 15 min Delay Period and 5 min Open Period (Figure 8).
  • Page 7 1. Connect Entry Device to the lock by plugging the cable into the lock port marked ENT. 2. Connect power to the lock through the Entry Device (9-volt battery) or by connecting a LA GARD battery box or AC Power Adapter to the lock port marked BAT.
  • Page 8 Figure 10 Figure 12 Figure 13 Figure 14 Figure 11 (P/N) 731.018 Rev H 12/14 • © copyright 2008-2014 Kaba Mas LLC page 8 of 11...
  • Page 9 SAVE SETUP CONFIGURATION Once the setup configuration has been completed, you may name and save the setup file (*.xml) for future use. 1. Click the Save button or on the Files tab at the top of the program and select Save (Figure 15). 2.
  • Page 10 8. Test unit operation several times before closing the door. NOTE: If default combinations are used, it is recommended that they be changed. New combination will not be accepted if it varies from the current combination by only one digit (+/-). (Example A: 1-1-1-1-1-1 to 1-1-1-1-1-3 is incorrect. Example B: 1-1-1-1-1- 1 to 1-1-1-1-3-2 is correct.) When selecting a combination, do not use a birthday or other predictable information that could give correlation between the user and the combination.
  • Page 11 ACTIVATE USERS 1. Enter Default Manager combination (all 5’s to length of combination) and hold down last digit of combination until lock double signals twice and the LED stays on. 2 PRESS 1. 3. Enter User number (1 - 9.) 4.