Fluke 323 User Manual page 17

Clamp meter
Hide thumbs Also See for 323:
Table of Contents

Advertisement

323/324/325
Users Manual
Continuity Beeper
323 .................................................... ≤70 Ω
324/325 ............................................. ≤30 Ω
Capacitance (324, 325)
Range...................................................... (100.0, 1000) µF
Resolution ............................................... (0.1, 1) µF
Accuracy ................................................. 1 % ±4 digits
Frequency with Jaw (325)
Range...................................................... 5.0 to 500.0 Hz
Resolution ............................................... 0.1 Hz
Accuracy ................................................. 0.5 % ±4 digits
Trigger Level ........................................... 5 to 10 Hz, ≥10 A
Contact Temperature (324, 325)
Range...................................................... -10.0 °C to 400.0 °C
Resolution ............................................... 0.1 °C
Accuracy ................................................. 1 % ±8 digits
Note: Temperature uncertainty (accuracy) does not include error of the thermocouple probe.
14
Shop for Fluke products online at:
10 to 100 Hz, ≥5 A
100 to 500 Hz, ≥10 A
MyFlukeStore
www.
1.888.610.7664
.com

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

324325

Table of Contents