INSTALLATION
3 - W i r e C o n n e c t i o n : P o w e r C o r d
W A R NING
• T h e m i d d l e ( n e u t r a l o r g r o u n d ) w i r e , w h i c h
i s w h i t e , o f a 3 - w i r e p o w e r c o r d o r a 3 - w i r e
c o n d u i t h a s t o b e c o n n e c t e d t o t h e m i d d l e
p o s t o f t h e m a i n t e r m i n a l b l o c k . T h e
r e m a i n i n g t w o w i r e s o f t h e p o w e r c o r d o r
c o n d u i t h a v e t o b e c o n n e c t e d t o t h e o u t s i d e
p o s t s o f t h e m a i n t e r m i n a l c o n n e c t i o n b l o c k .
Failure to do so can result in electrical shock,
severe personal injury or death.
In s t a l l t h e p o w e r c o r d a s f o l l o w s :
For power cord installations, hook the strain relief
over the power cord hole (1
rear of the oven. Insert the power cord through the
strain relief and tighten it.
D o n o t i n s t a l l t h e p o w e r c o r d w i t h o u t a s t r a i n
r e l i e f .
1
Remove the lower 3 screws from the terminal
block and retain them.
2
Insert the 3 screws through each power cord
terminal ring and into the lower terminals of
the terminal block. Make sure that the center
(neutral) wire, which is white, is connected to the
center lower position of the terminal block.
3
Tighten the 3 screws securely into the terminal
block. Do not remove the ground strap
connections.
3 - w i r e c o n n e c t i o n
Black White Red
Conduit
connection plate
If screws are not tightened securely, it can result in
electrical spark and severe personal injury or death.
3
/
") located below the
8
Terminal
block
4 - W i r e C o n n e c t i o n : P o w e r C o r d
W A R NING
• O n l y a 4 - c o n d u c t o r p o w e r - s u p p l y c o r d
k i t r a t e d 1 2 0 / 2 4 0 v o l t s , 5 0 a m p e r e s a n d
m a r k e d f o r u s e w i t h r a n g e s w i t h c l o s e d -
l o o p c o n n e c t o r s o r o p e n e d s p a d e l u g s w i t h
u p t u r n e d e n d s s h a l l b e u s e d .
T h e w h i t e m i d d l e ( n e u t r a l ) w i r e o f t h e p o w e r
c o r d o r 4 - w i r e c o n d u i t h a s t o b e c o n n e c t e d
t o t h e m i d d l e p o s t o f t h e m a i n t e r m i n a l
b l o c k . T h e o t h e r t w o w i r e s o f t h e p o w e r
c o r d o r c o n d u i t h a v e t o b e c o n n e c t e d t o
t h e o u t s i d e p o s t s o f t h e m a i n t e r m i n a l
c o n n e c t i o n b l o c k . T h e 4 t h g r o u n d w i r e
( g r e e n ) m u s t b e c o n n e c t e d t o t h e f r a m e o f
t h e r a n g e w i t h t h e g r o u n d s c r e w . Failure
to do so can result in electrical shock, severe
personal injury or death.
In s t a l l t h e p o w e r c o r d a s f o l l o w s :
D o n o t i n s t a l l t h e p o w e r c o r d w i t h o u t a s t r a i n
r e l i e f .
1
Remove the lower 3 screws from the terminal
block and retain them.
2
Remove the ground screw and bend the end of
the ground strap up so the slot is over the hole
of the center screw removed in step 1.
3
Insert the ground screw into the power cord
ground wire (green) terminal ring and secure it to
the range frame.
4
Insert the 3 screws through each power cord
terminal ring and into the lower terminals of the
terminal block. Make sure that the white center
(neutral) wire is connected to the center lower
position of the terminal block.
5
Tighten the 3 screws securely into the terminal
block. The center screw now attaches the bent
up ground strap to the block.
4 - w i r e c o n n e c t i o n
Black White Red
Ground
screw
If screws are not tightened securely, it can result in
electrical spark and severe personal injury or death.
Terminal
block
Ground
strap
Bend strap up
and attach
Conduit
connection plate

Advertisement