8.1 Limiting voltage range

The limiting voltage range is maximum voltage range that power supply and digital or analog input/output
interfaces can withstand.

8.1.1 Absolute voltage range

The absolute voltage range of NL668-LA series module is shown as table 8-1.
Parameter
description
VBAT
Power supply
GPIO
Digital IO supply voltage

8.1.2 Operating voltage range

: logic low level ; V
V
L
V
L
Parameter
Min
Digital input
-0.3
Digital output
-
Parameter
VBAT
USIM_VDD

8.2 Environment temperature range

The recommended operating temperature range of NL668-LA series module.is -30℃~+75℃. When
module operating at limited temperature range, some RF indexes may exceed standard, so module
application terminal should consider temperature control measurement. The module application terminal
is recommended storage in certain temperature conditions. Modules out of the temperature range may
not operate or may be damaged.
Temperature
Operating temperature
Reproduction forbidden without Fibocom Wireless Inc. written authorization - All Rights Reserved.
FIBOCOM NL668-LA Series Hardware User Manual
Table 8- 1 Absolute Voltage Range
: logic high level ;
H
Max
0.6
0.45
I/O
Min
PI
3.3
PO
1.7/2.75
Table 8- 2 Operating Voltage Range
Min
-30
Min
Typ
-0.3
3.8
-0.3
1.8
V
H
Min
1.2
1.35
Typ
3.8
1.8/2.85
Typ
25
Max
Unit
4.7
V
2.0
V
Max
2.0
-
Max
4.3
1.9/2.95
Max
Unit
75
Page 54 of 65
Unit
V
V
Unit
V
V

Advertisement