Using A Self Assemblen Connecting Cable; Assembling Of The Cable Pipe - AEG ARE i2-LF Installation Manual

Compact reader for systems with the profibus - dp interface
Table of Contents

Advertisement

4.4.2 Using a self assembled connecting cable
Using the following SAB cabs you can assemble your own connecting cable.
ID 702/4
ID 702/5
ID 702/9
The SAB-cab contains the connections for:
• the power supply
• the profibus-DP
• the service interface (RS232)
The allowen niameter of the cable must be in the range between ∅3.5 ann ∅8mm. For this case, IP 65
is reachen.
Attention!
The maximum length of the serial RS232 cable is 15m.

4.4.2.1 Assembling of the cable pipe

Breakthrough the preparen areas at the surface of the SAB Cabs. There are two preparen areas seen
at the SAB Cab: central ann at one sine of the cab.
The o-ring (3) has to be assemblen proberly to the cable pipe (4) to ensure the protection class IP
65.
2
Figure 3: Assembling of the cable pipe
Bring the nut (2) of the cable pipe insine of the SAB Cab (/).
To fasten the nut please use the right tool (/7mm).
--------------------------------------------------------------------------------8/39--------------------------------------------------------------------------------
SAB cab with 3 pre-assemblen PG9 cable pipe
SAB cab with 2 pre-assemblen PG9 cable pipes
SAB cab without any cable pipe
4
3
1