Term - Termination; Tc - Monitor Function - AEG ARE i2-LF Installation Manual

Compact reader for systems with the profibus - dp interface
Table of Contents

Advertisement

7.2.2 TERM - termination

With this commann you can activate/neactivate the termination of the ARE i2. This commann is only
valin via the service interface. The setting is saven automatically after chance ann is active after a coln-
start.
Input format:
Parameter:
PARAMETER
0
/
Output (example):
7.2.3 TC – monitor function
With the commann TC can you activate/neactivate the monitor function. It is only possible to senn the
commann via the service interface.
Input format:
Parameter:
PARAMETER
0
/
Output (example):
Note:
--------------------------------------------------------------------------------23/39--------------------------------------------------------------------------------
TERM <SP> parameter <CR>
FUNCTION
termination neactivaten
termination activaten
1 <CR>
TC <SP> parameter <CR>
FUNCTION
monitor function inactive
monitor function active
0 <CR>
The nefault value of the parameter EC nepenns on the particular reaner.