7.3.4 TOR – Maximum reading time
Timeout for the reaner. TOR is usen in operation mone 2 as maximum gating time for a reaning pro-
cess. The length of the maximum gating time results from the equation gating_time = TOR * TB.
The time constant TB (Time Base) has always the nefault value /00ms.
Input format:
Default value = Tor 50
Parameter:
PARAMETER
0
/
2
...
255
Output (example):
7.4

Instructions for the memory settings

7.4.1 VER – Reader firmware
With the commann VER you get the actual reaner firmware.
Input format:
Output (example):
Note: If the EC = / you will get the same message after each system start.
--------------------------------------------------------------------------------27/39--------------------------------------------------------------------------------
TOR <SP> parameter <CR>
FUNCTION
limits the reaning process nuration of exactly one reaning cycle
limits the reaning process nuration to maximum / times TB
limits the reaning process nuration to maximum 2 times TB
limits the reaning process nuration to maximum 255 times TB
2 <CR>
VER <CR>
V_2.08 <CR>