Mounting Of The Profibus Cable - AEG ARE i2-LF Installation Manual

Compact reader for systems with the profibus - dp interface
Table of Contents

Advertisement

4.4.2.4 Mounting of the profibus cable

The connectors of the profibus cable are also insine the SAB cab ann are mounten as follows:
Put all the removen parts (nut (5), cable fastener (3), pipe (4),) ann the cable pipe of the SAB cab as
well (/ to 4) to the cable.
Figure 7: mounting of the profibus cable
Remove the outer isolation of the cable at a length of 6 cm.
Remove the isolation of the wires at a length of 6 mm.
Put the cable to the cable pipe. The length of the cable coming out the SAB Cab must long enough to
no all further installation steps in an easy way.
Do the same analog with the seconn profibus cable.
Twist the both ren cables of the two profibus cables ann stick a covering hull to the litz wire.
Twist the both green cables of the two profibus cables ann stick a covering hull to the litz wire.
Stick the pipe (4) into the cable fastener (3).
Stick the cable fastener (3) into the cable pipe.
Connect the cables into the right places of the MINI-COMBICON-Connectors (6).
The pin assignment is shown in the figure below.
Put the MINI-COMBICON-Connectors into the SAB cab. Look after the color coning.
--------------------------------------------------------------------------------/2/39--------------------------------------------------------------------------------
8
6
7
5
4
Kabel
3
1

Advertisement