Download Print this page

Introduction - Pickering 40-670 User Manual

Very high density multiplexer module
Hide thumbs Also See for 40-670:

Advertisement

pickering
GENERAL
The 40-670 range of Very High Density Multiplexer Modules which form part of the System 40 PXI Programmable
Switching system feature a wide range of switching congurations. Typical applications include signal routing in ATE
and data acquisition systems.
The 40-670 multiplexer may be operated as a conventional multiplexer
with break-before-make action when a new channel is selected. In
addition multiple channels may be simultaneously selected (not available
in 1 pole mode).
Built-in Automatic Isolation Switching (available in 1, 2 and 4 pole mode)
connects only the currently active multiplexer bank to the analogue
common, thereby keeping capacitive loading and leakage currents in
large multiplexer systems to a minimum. Larger multiplexers may be
constructed by daisy chaining the common signals from multiple PXI
cards.
Connections are made via a front panel 200 pin connector.
The screened version (40-670-022-S) is suitable for switching frequencies
up to 100MHz. It may also be used with low frequency signals where very
good isolation and crosstalk performance is required.
The Multiplexer Module is provided in the following congurations (typical schematics are provided in Figure 1.1):
Single Mode
V H D MUX 198 Channel 1 Pole 40-670-022-198/1
Multi-Mode
H D 99 Channel 1 Pole 40-670-021-99/1
H D 49 Channel 2 Pole 40-670-021-49/2
H D 24 Channel 4 Pole 40-670-021-24/4
H D 10 Channel 8 Pole 40-670-021-10/8
H D 5 Channel 16 Pole 40-670-021-S-5/16
V H D MUX 99 Channel 2 Pole 40-670-022-99/2
V H D MUX 49 Channel 4 Pole 40-670-022-49/4
MECHANICAL DESCRIPTION
The 40-670 range of Multiplexer Modules conform to the 3U height (128mm)
Eurocard standard. Each module comprises the following:
CPCI Ejector Handle
Front Panel mounted 200-way SCSI 2 Type connector
100 Ruthenium Reed Switches, or
100 Screened Ruthenium Reed Switches (-S) versions only
Two spare Reed Switches (Relays RL101 and 102)
Compact PCI backplane connector
PCI Bridge (U1)
Control Logic
The front panel is secured to the PCB by two M2.5 x 6mm pan-head posi-drive screws.
VERY HIGH DENSITY MULTIPLEXER MODULE 40-670
SECTION 1 - INTRODUCTION
V H D MUX 24 Channel 8 Pole 40-670-022-24/8
V H D MUX 10 Channel 16 Pole 40-670-022-10/16
V H D MUX 5 Channel 32 Pole 40-670-022-5/32
H D Screened 99 Channel 1 Pole 40-670-021-S-99/1
H D Screened 49 Channel 2 Pole 40-670-021-S-49/2
H D Screened 24 Channel 4 Pole 40-670-021-S-24/4
H D Screened 10 Channel 8 Pole 40-670-021-S-10/8
H D Screened 5 Channel 16 Pole 40-670-021-S-5/16
SECTION 1 - INTRODUCTION
Page 1.1

Hide quick links:

Advertisement

loading