PUMP PERFORMANCE CURVE
MODEL WM211/WM264/WM266/WM270
WITH DISCHARGE PIPE INSTALLED
35
10
30
8
25
20
6
266
15
4
10
2
5
0
20
40
GALLONS
LITERS
0
80
160
FLOW PER MINUTE
C
D
A
B
1
1
1
1
12
12
5
13
4
4
2
4
All dimensions are in inches.
A
G

PERFORMANCE CHARACTERISTICS

270
264
211
60
80
100
120
240
320
400

DIMENSIONAL DATA

H
E
F
G
1
3
1
14
17
42
24
8
16
2
J
B
© Copyright 2013 Zoeller Co. All rights reserved.
TOTAL DYNAMIC HEAD/FLOW
SEWAGE AND DEWATERING
WM211
MODEL
MODEL 101
Feet
Meters
Gal.
Liters
5
1.5
73
276
10
3.0
39
148
15
4.6
19
72
20
6.1
--
--
25
7.6
--
--
Shut-off Head:
17.5 ft.(5.3m)
I
J
1
1
13
20
2
2
3
PER MINUTE
WM264
WM266
MODEL 100
MODEL 102
Gal.
Liters
Gal.
Liters
105
397
110
416
67
254
78
295
27
102
40
151
--
--
--
--
--
--
--
--
17.5 ft.(5.3m)
19.2 ft.(5.9m)
I
H
C
E
F
D
WM270
MODEL 103
Gal.
Liters
112
424
90
341
67
254
45
170
23
87
30.0 ft.(9.1m)
009966