Page 24
S1 DIP
Switch #
7
No solar system installed.
Air temperature is
displayed.
After thermostat setting
8
has been reached, heater
will remain OFF for three
(3) minutes.
S2 DIP
Switch #
1
6.3 DIP Switch Settings for Solar/Heat Pump
This table shows how to configure the system for SOLAR PRIORITY or HEAT
PUMP PRIORITY.
DIP
GREEN 10-PIN
S2-1
TERMINAL
OFF
No sensor
installed
OFF
Sensor
installed
OFF
OFF
The AquaLink
RS will
®
be able to control a Solar
Heating system (If a solar
sensor is connected to the
solar sensor input)
RS485 HEAT
BAR
Not connected
Not connected
Jandy
®
Changes air sensor to solar
sensor. Air temperature
no longer displayed.
Adjustable Freeze Kit
must be added for freeze
protection.
Heat Pump installed; after
thermostat setting has
been reached, heater will
remain OFF for five (5)
minutes.
The AquaLink RS will be
able to control a Heat
Pump. (The AquaLink RS
will not be able to control
a Solar Heating system.)
PUMP
In this configuration there
is no Solar Heating and
no Heat Pump. Extra
AUX is available.
In this configuration there
is Solar Heating and
there is Solar Priority.
There is no Heat Pump.
AquaLink
RS Conversion Kit
®
ON
ON
DESCRIPTION
Need help?
Do you have a question about the AquaLink RS Conversion Kit and is the answer not in the manual?