Technical Specifications
Technical Specifications
Model Number
Temperature Sensor Measurement Range
Operating Temperature Range
Storage Temperature Range
Ambient humidity range during
transport, storage and use
Rated Temperature Resolution
Rated Temperature Accuracy
Probe Compatibility
Sensor Technology
Sensor Reaction Time
Clock accuracy
Recording Capacity
Statistics memory
Memory type
Sampling Interval
Start options
Alarm functions
Vibration
Shock
EMC compliance
Environmental
1
Values above 199.9 °F cannot be shown on the display. The values will, however, be recorded and shown in LogTag
and in the PDF
UTRED30-16 User Guide
UTRED30-16
-40 °C to +99 °C (-40 °F to +210 °F
-30 °C to +70 °C (-22 °F to +158 °F)
-10 °C to +40 °C (32 °F to +104 °F)
0 to 95 %RH
0.1 °C (0.2 °F) for measurements -40 °C to +50 °C (-40 °F to +122 °F)
0.2 °C (0.4 °F) for measurements +50 °C to +70 °C (+122 °F to +158 °F)
0.3 °C (0.5 °F) for measurements +70 °C to +80 °C (+158 °F to +176 °F)
0.4 °C to 0.6 °C (0.7 °F to 1 °F) for measurements +80 °C to +99 °C (+176 °F to +210 °F)
Please see resolution chart in
Accuracy and Resolution
Better than ±0.8 °C (±1.4 °F) for -40 °C to -20 °C (-40 °F to -4 °F), typically ±0.5 °C (0.9 °F)
Better than ±0.5 °C (±0.9 °F) for -20 °C to +40 °C (-4 °F to +104 °F), typically ±0.3 °C (0.6 °F)
Better than ±0.8 °C (±1.4 °F) for +40 °C to +70 °C (+104 °F to +158 °F), typically ±0.7 °C (1.3 °F)
Better than ±1.2 °C (±2.2 °F) for +70 °C to +99 °C (+158 °F to +210 °F), typically ±1 °C (1.8 °F)
Please see accuracy chart in
Accuracy and Resolution
All ST100 precision thermistor external probes can be interchangeably connected to the
UTRED30-16. Please refer to the page for External Probes on the LogTag Recorders website.
Precision electronic thermistor
According to Probe
Quartz crystal-locked real time clock, rated accuracy ±25ppm @ 25 °C (equiv to 2.5 seconds/day)
Rated temperature coefficient is -0.034±0.006ppm/°C (i.e. typically +/-0.00294seconds/day/°C)
16129 real time temperature values, giving
67 days @ 6 min logging;
l
112 days @ 10 min logging; or
l
168 days @ 15 min logging
l
Supports continuous logging ("wrap-around") or specific recording period
For displaying statistics on the LCD
Trip min/max values
l
Max/Min values for the past 30 days
l
Alarm duration values for the past 30 days
l
AM/PM Inspections for the past 30 days
l
Total time above/below alarm thresholds
l
Non volatile
Configurable from 30 seconds to 18 hours
Push button start with optional configurable start delay from 1 minute to 72 hours
l
Date/time start up to 180 days in the future
l
Total of 6 alarms
l
Up to 5 configurable upper alarms
l
Up to 5 configurable lower alarms
l
indicator on display, linked to alarms
l
Alarm arrows linked to thresholds
l
Red Alert LED
l
Audible alarm
l
Withstands vibration specification as detailed in EN12830:2018
Withstands shock specification as detailed in EN12830:2018
l
Withstands 5 drops from 1m onto smooth concrete floor without loss of function or
l
calibration
EC EMC directives for Emission (IEC/CISPR 32: 2015)
l
RTCA DO-160G:2010, section 21
l
Electrostatic discharge/Immunity (IEC/CISPR 24 Ed. 2.1: 2015)
l
Complies with FCC Part 15 Subparts A and B
l
IEC 60529: IP61 with USB cap fitted and hung vertically
1
)
57
Analyzer
®
Need help?
Do you have a question about the UTRED30-16 and is the answer not in the manual?
Questions and answers