sending fewer pounds back to the recycler.
• A TigerStop
Dynamic Optimizing
®
Fabricators and skilled workers can better use their time managing the shop or doing work requiring
greater expertise.
Contact TigerStop Customer Service to Enable Your Optimizing Upgrade!
Maintenance Schedule
Maintenance Schedule
Record the following settings for future reference.
Serial Number:
Min Limit:
Max Limit:
Scale:
Kerf:
Lash:
Daily
1. Clean all dirt and debris from drive areas:
• Cable Track
• Pinion Gear
• Rack
2. Check all cables for damage.
3. Check calibration, if necessary.
Weekly
1. Visually inspect the rack and pinion for lubrication. Only use molybdenum disulfide lubricants.
2. Visually inspect the cable track for objects that may have fallen into or on the track.
Quarterly (Every 3 Months)
1. Check rack to ensure that the sections are tight and aligned properly (see page 9).
2. Check the pinion gear to ensure that it is properly tensioned (see page 10).
3. Run a motor drive test and record the data in th maintenance log. If drive numbers are above
12000 (check), contact TigerStop Customer Service.
Yearly
1. Thoroughly inspect all cables and air lines running through the cable tray.
2. Perform a data log to ensure system accuracy. A downloadable copy can be found at www.
tigerstop.com/support.
32
station can even be used by an unskilled worker. Top paid
™
(360) 254-0661
service@tigerstop.com
MxP =
MxN =
P+ =
P- =
Drive Test Results
Need help?
Do you have a question about the TigerRack and is the answer not in the manual?
Questions and answers