January 2017
Appendix C: Sensor specifications
Table C-1 Millennium sensor specifications
Operating temperature range
Weight
Enclosure material
Range of detection
Accuracy
Response time
Linearity/repeatability
Certification*
* QPS Marking applies to MLP-A-SC1100, MLP-A-SC1100-SS, MLP-AR-SC1100, and MLP-AR-SC1100-SS controllers only.
40
-40 °F to 185 °F (-40 °C to 85 °C)
0.2 lb. (0.1 kg)
Powder coated or anodized aluminum (optional stainless steel)
0 to 100% LEL of most hydrocarbons and hydrogen
±3% LEL up to 50%LEL, ±5% LEL above 50% LEL
<10 seconds to T50, < 30 seconds to T90
±3% LEL / ±2% LEL
Class 1, Division 1, Groups B, C, and D T5 Type 3R
Ex d IIB+H2 T5 Gb
Performance certified to CSA C22.2 No. 152 when connected to Millennium Controller
Operations Manual
FGD-MAN-0047