The screw is marked with the symbol

E.10.3 Power cable

Unless otherwise specified, our appliances are not equipped
with a power cable.
The installer must use a flexible cable having characteristics
not lower than the H07RN-F rubber insulated type.
Protect the section of cable outside the appliance with a metal
or rigid plastic tube.
WARNING
If the power cable is damaged, it
must be replaced by the Cus-
tomer Care or in any case by
qualified personnel, in order pre-
vent any risk
WARNING
The manufacturer declines any
liability for damage or injury
resulting from breach of the
above rules or non-compliance
with the electrical safety regula-
tions in force in the country
where the machine is used

E.10.4 Circuit breaker

Verify that a safety circuit breaker is installed between the
power cable of the appliance and the mains electric line.
F
INSTRUCTION FOR THE USER
F.1

Fry top use

General precautions
• The appliance is intended for industrial use by trained
personnel.
• Do not use the appliance empty or in conditions that
compromise its optimum efficiency.
Also, if possible, preheat the appliance immediately before
use.
• The fry top is designed for direct cooking of food on the hot-
plate (hamburgers, chops, eggs, sausages, fish, vegeta-
bles, etc.).
Any other use is improper.
• Every day before use, when the appliance is cold, empty the
oil collection tray.
• Do not use the fry top to heat pots or pans.
The available models are:
• Fry top 400mm
It consists of a single cooking zone controlled by a thermo-
static gas valve (gas version) or a thermostat (electric
version).
The bulb for measuring the temperature is located in the
middle of the plate;
• Fry top 800mm
It consists of two cooking zones (left side and right)
controlled by two thermostatic gas valves (gas version) or
by two thermostats (electric version), one for each zone.
The bulbs for measuring the temperature are located in the
middle of the plate (left and right side respectively).
.
The contact opening max. distance and leakage current must
comply with the local safety regulations.
E.11

Safety thermostat

Appliances equipped with safety thermostat (overheating
safety thermostat) that trips off automatically when temper-
atures exceed a set value, shutting off the gas supply (gas
appliances) or the electricity (electric appliances).
IMPORTANT
Resetting of the safety thermostat must be carried
out by specialised personnel; contact the Customer
Care.
IMPORTANT
"Positive trip" effect of the safety thermostat (used
on some equipment type as per norms prescrip-
tions) interrupts the unit operability (heating) even
in case the capillary is cut.
Similar effect, but with no damage for the safety
thermostat, can happen if the machine body
temperature drops below -10℃: in such cases, it is
required to reset the safety thermostat while instal-
ling the machine, hence before connecting it to the
mains.
IMPORTANT
On electric heated machines, only reset safety
thermostat after disconnecting from the mains.
Failure to disconnect from the mains causes the
safety thermostat to brake and the unskilled person
to risk electrocution.
Tampering with the safety thermostat invalidates
the original manufacturer warranty.
F.2

Gas models

F.2.1

Lightning on

The gas control knob "A" has the following positions:
"Off"
"Pilot ignition"
100 –
"Temperatures"
280 ℃
Lighting the pilot flame
1. Turn knob "A" anticlockwise from
hold it down.
2. At the same time press button "B" repeatedly until the pilot
burner lights.
B
C
A
to
position and
19

Advertisement

Table of Contents
loading

Table of Contents