LG LRG4111ST Service Manual page 38

Freestanding gas single oven range
Hide thumbs Also See for LRG4111ST:
Table of Contents

Advertisement

WARNING
• Turn off the electrical supply and
gas supply going to the range.
• Replace all panels and parts before
operating.
• RECONNECT all grounding devices.
- Failure to do so can result in severe personal
injury, death or electric shock.
CAUTION
• Use caution when handling sheet
metal parts while servicing the
range.
- Some parts may have sharp edges, which
could result in injury.
• Natural Gas Orifice Specifications
BURNER OUTPUT RATINGS; BTU/HR
Natural Gas, 5" W.C.P
MODEL
BTU RATE
BURNER
[LRG4111]
LF
12,000
Q
LR
9,100
RR
5,000
LR
M
RF
17,500
CTR
9,100
BROIL
15,500
LF
BAKE
19,000
M
CTR
C
Q
Orifice Locations for Natural Gas
[ LRG4111]
V
V
C
CONVERSION TO LP GAS
LRG4111
ORIFICE CODE
F
C
V
Broil and Bake
AA
RR
W
H
V
A
RF
H
I
Q
Broil and Bake
AA
H
4) To prevent leakage, make sure the orifice
spuds are securely screwed into the gas
supply tubes.
5) For the right front burner of LRG4113ST, the
choke and self threading screw will be
needed as shown Fig Insert the choke into
the burner base, then insert the set screw
into the burner base and tighten securely.
Make sure the screw head is against the
shoulder (within choke notch), so it does not
have any rotational movement.
<Fig>
7) Put the old orifice spuds into conversion kits
and place back on the range for possible
future conversion.
NOTE: If an orifice spud is accidentally
dropped, the cooktop plate can be
raised (see the page 3-6)
5-3
Self threading
screw
Choke
18.5k burner
base

Advertisement

Table of Contents
loading

Table of Contents