Epson WF-R8590 Service Manual page 30

Revisione color ink jet printer
Hide thumbs Also See for EPSON WF-R8590:
Table of Contents

Advertisement

 EPSON WF-R8590/WF-R8591/WF-R8593
Error type
Opposite side wrong contact detection distance
0x13
error 
0x14
Measurement failure error
0x20
LED light error  
0x21
ALD PID excess speed error  
0x22
ALD PID reverse error  
0x23
ALD PID Lock error  
0x24
ALD PID acceleration lock  
0x25
ALD PID excess load error  
0x26
ALD PID driving time error  
Option error 
0x30
MAIN-B connection error 
MAIN-A connection error 
0x31
0x36
Paper jam error  
0x41
FB PID excess speed error  
0x42
FB PID reverse error  
0x43
FB PID lock error  
0x44
FB PID acceleration lock  
Table 1-4. Fatal Error List (ADF/Scanner)
Error code
 Fatal Error Code List
Error name
• CIS Unit failure
• Scanner Housing failure (Including wrong attachment of the origin mark)
• SCN Main board failure
• Scanner FFC failure
• Scanner FFC connection failure
• Scanner motor failure
• Scanner motor connection failure
• Scanner drive mechanism was overloaded
• CIS Unit failure
• SCN Main board failure
• ALD motor failure
• Motor driver failure
• Cable disconnection
• ALD motor failure
• Motor driver failure
• Cable disconnection
• ALD motor failure
• Motor driver failure
• Cable disconnection
• ALD motor failure
• Motor driver failure
• Cable disconnection
• ALD motor failure
• Motor driver failure
• Cable disconnection
• ALD motor failure
• Motor driver failure
• Cable disconnection
• Main Board failure
• Connected error between the Main board and SCN Main Board
• SCN Main Board failure
• Main Board failure
• Scanner FFC connection failure
• Paper jam
• Foreign object
• ADF Encoder failure (contaminated/detached scale, Encoder Board
failure)
• Paper jam
• Motor driver failure (SCN Main board failure)
• ADF Encoder failure (contaminated/detached scale, Encoder Board
failure)
• Paper jam
• ADF Encoder failure (contaminated/detached scale, Encoder Board
failure)
• ADF motor failure
• ADF drive mechanism overload (assembling failure, lubrication failure)
• Cable disconnection
• ADF Encoder failure (contaminated/detached scale, Encoder Board
failure)
• ADF motor failure
• ADF drive mechanism overload (assembling failure, lubrication failure)
• Cable disconnection