Dismantling the CGS-2L/R side cylinder casing:
Fig.: Dismantling the CGS-2L/R side cylinder casing
Separation
For simpler transportation, the heating module (A) can be
separated from the cylinder (B)
- Open control unit flap (1)
- Remove both front panels from A + B (2) (also see chap-
ter 7)
- Release union nut G3/4" for DHW/cold water supply
pipes at heating module A (3)
- Close control unit flap (4)
- Disconnect earth cable between A and B from the rear
panel of heating module A (4.1)
- Remove locking screws on the back (5)
- Remove cylinder sensor from sensor well and place near
the heating pump of the heating module (6)
- Push heating module A back to release it from all 4 lock-
ing mechanisms (7)
- Lift up heating module A to remove it and lie it down on its
back (8)
Refit in reverse order
Replace flat gaskets in the connections (3).
Always check the tightness of the connections (3)
after filling the system. Check that the earth cable
is fitted correctly.