G.
FOR REMOTE MODELS
LABEL LEAD WIRES AS SHOWN.
LEADS TO BE 6" FROM HOUSING
FDDB-208/240V
WIRE #'S 6 AND 12 TO BE 10 GA. - 450°C.
WIRE # 1 TO BE 12 GA. - 100°C.
ALL OTHER WIRES TO BE 12 GA. - 250°C.
H.
ONE LAMPHOLDER
18,24,30 MODELS
FDDB-208/240V WIRING DIAGRAM
ELEMENT
12
ELEMENT
6
FDDLB-120V WIRING DIAGRAM
FOR REMOTE MODELS
LABEL LEAD WIRES AS SHOWN.
LEADS TO BE 6" FROM HOUSING
TWO LAMPHOLDERS
36,42,48,54 MODELS
15
15
ELEMENT
ELEMENT
FDDLB-120V
WIRE #'S 6 AND 12 TO BE 10 GA. - 450°C.
WIRE # 1 TO BE 12 GA. - 100°C.
ALL OTHER WIRES TO BE 12 GA. - 250°C.
B-T'STAT
11
B-L1
13
B-L2
F-T'STAT
5
A-L1
7
A-L2
THREE LAMPHOLDERS
60,66,72 MODELS
15
14
C-L1
15
8
B-T'STAT
11
12
B-L1
7
8
F-T' S TAT
6
5
A-L1
3
7
A-LN
BACK-SW
1
4
2
5
10
3
6
FRONT-SW
8
9
4
1
5
2
4
3
6
1
2
3
LIGHT-SW
1
4
2
5
3
6
18
BACK-SW
13
4
1
5
2
10
3
6
17
FRONT-SW
9
4
1
5
2
4
3
6
16
16
1
2